User Guide
A-26 Ampex 1308910-01
Model No.
Running Head
CHS Failure, Error, and Warning Codes Returned Sense Data
WARNING MESSAGES (412)
2001 (0x7D1) +24Vdc supply is indicating greater than 26 volts
2002 (0x7D2) +24Vdc supply is indicating less than 22 volts
2003 (0x7D3) +5Vdc supply is indicating greater than 5.5 volts
2004 (0x7D4) +5Vdc supply is indicating less than 4.5 volts
2005 (0x7D5) -15Vdc supply is indicating greater than 16 volts
2006 (0x7D6) -15Vdc supply is indicating less than 14 volts
2007 (0x7D7) Drive elevator roller mda integrated circuit [U4] is over temperature
2008 (0x7D8) Elevator calibration data is cleared, recalibrate
2009 (0x7D9) Elevator calibration data is out of range
2010 (0x7DA) Elevator calibration data read checksum error
2011 (0x7DB) Elevator failed to slow down for middle vane
2012 (0x7DC) Elevator is already parked
2013 (0x7DD) Elevator mda integrated circuit #1 [U20] is over temperature
2014 (0x7DE) Elevator mda integrated circuit #2 [U9] is over temperature
2015 (0x7DF) In-arm calibration data is cleared, recalibrate
2016 (0x7E0) In-arm calibration data is out of range
2017 (0x7E1) In-arm calibration data read checksum error
2018 (0x7E2) Loader frame is not positioned to rack
2019 (0x7E3) Loader port roller mda integrated circuit [U3] is over temperature
2020 (0x7E4) Middle vane sensor positioned too high
2021 (0x7E5) Middle vane sensor positioned too low
2022 (0x7E6) No available elevator bin for the cartridge in drive
2023 (0x7E7) Out-arm calibration data is cleared, recalibrate
2024 (0x7E8) Out-arm calibration data is out of range
2025 (0x7E9) Out-arm calibration data read checksum error
2026 (0x7EA) Tape Drive +5 Vdc power is missing
Table A-4. CHS Failure, Error, and Warning Codes (Continued)
CHS Code Description