User Guide

A-16 Ampex 1308910-01
Model No.
Running Head
CHS Failure, Error, and Warning Codes Returned Sense Data
A.5 CHS Failure, Error, and Warning Codes
Table A.5 lists CHS failure, error, and warning codes the ACL might report in the data returned
for aclGetStatus(). This information is intended for Ampex factory personnel as
interpretation of the codes requires a detailed understanding of ACL internal operation.
Note: DST 712 information is currently not available.
Table A-4. CHS Failure, Error, and Warning Codes
CHS Code Description
CHS WARNING TALLY MESSAGE NUMBERS (812)
0x00 (0x00) No warning message
0x01 (0x01) Bin was empty on a get
0x02 (0x02) CHS was empty on a put
0x03 0x0(3) No barcode label detected
0x04 (0x04) Inverted barcode label read
0x05 (0x05) Unreadable barcode label
0x06 (0x06) Barcode printed wiring assembly (PWA) failed self test
0x07 (0x07) No cartridge on a get
0x08 (0x08) Readall procedure aborted
0x09 (0x09) I/O port occupied for a put
0x10 (0x0A) I/O port sensor data error
0x11 (0x0B) Put retry needed to complete
0x23 (0x17) Get retry needed to complete
0x24 (0x18) Drive not home for a get
0x25 (0x19) Cart not in I/O detent for get
0x26 (0x1A) Cartridge sensor error on a put
0x27 (0x1B) Cart rescue required for a get
0x28 (0x1C) Z-axis vane detector error
RESET PROCEDURE WARNINGS (812)
0x100 (0x64) Cartridge purged to I/O port
0x101 (0x65) Offset read checksum error
0x102 (0x66) Excessive offset magnitude