Returned Sense Data Vendor-Specific ACL Condition Codes
0x0B 0x55 0xBA 0x3A
Aborted Command
AC_ROBOT_GET_FAIL_UNRECOVERED
Aborted Command, CHS Could Not
Recover from Get Failure
(812)
The ACL was executing a move
command which involves getting a
cartridge from one location and putting
it in another. The get was successful,
but the put failed. The ACL was unable
to restore the cartridge to its original
location and the bin database is in a
different state than when the Move
command was initiated.
Read Element Status to
determine current element status.
0x0B 0x55 0xBB 0x3B
Aborted Command
AC_ROBOT_COMMAND_ABORTED
Aborted Command, CHS Command
Aborted by Host
The ACL aborted the command in
response to a message received over the
SCSI bus.
Retry the command.
0x0B 0x5A 0x00 0x2C
Aborted Command
AC_ROBOT_IS_OFFLINE
Aborted Command, CHS is Off-line
(412)
Off-line operation was selected at the
front panel while the ACL was
executing a command.
Change mode to on-line using
front-panel message screen
buttons. The CHS will
automatically perform any
recovery or initialization
procedures required.
0x0B 0x5A 0x97 0x17
Aborted Command
AC_RBT_DOORS_OPEN
Aborted Command, Door Open
A cabinet door was opened while the
ACL was executing a command.
Close all doors (for an 812 ACL,
also reset the MDA POWER
switch). The ACL automatically
performs any recovery or
initialization procedures
required.
Table A-3. Vendor-Specific ACL Condition Codes (Continued)
ACL
Sense ASC ASCQ Condition
Key Code
Error Enumeration,
String, and Condition
Recovery Procedure