User Guide

A-14 Ampex 1308910-01
Model No.
Running Head
Vendor-Specific ACL Condition Codes Returned Sense Data
0x05 0x3B 0x0D 0x08
Illegal Request
AC_DEST_FULL
Illegal Request, Destination Bin
Full
The storage bin already contains a
cartridge.
Either you specified an incorrect
element address or your
application is not synchronized
with the ACL internal database.
Read Element Status to
determine the current status of
the ACL element(s).
0x05 0x3B 0x0D 0x1F
Illegal Request
AC_TXP_CARTRIDGE
Illegal Request, Destination
Drive Full
The tape drive already contains a
cartridge.
0x05 0x3B 0x0E 0x07
Illegal Request
AC_SRC_EMPTY
Illegal Request, Source Bin
Empty
There is no cartridge in the storage bin.
0x05 0x3B 0x0E 0x1E
Illegal Request
AC_TXP_NO_CARTRIDGE
Illegal Request, Source Drive
Empty
There is no cartridge in the tape drive.
0x06 0x29 0x00 0x45
Unit Attention
AC_ROBOT_RESET_UNIT_ATT
Unit Attention, ACL Reset
Indicates this is the first command sent
by the initiator after the ACL completed
a boot sequence.
The application software might
have to be re-initialized.
0x0B 0x55 0xB9 0x39
Aborted Command
AC_ROBOT_GET_FAIL_RECOVERED
Aborted Command, CHS Recovered
from Get Failure; No Action
Required
(812)
The ACL was executing a Move
command which involves getting a
cartridge from one location and putting
it in another. The get was successful,
but the put failed. The ACL was able to
restore the cartridge to its original
location and the bin database is in the
original condition it was in before the
Move command was attempted.
Not required.
Table A-3. Vendor-Specific ACL Condition Codes (Continued)
ACL
Sense ASC ASCQ Condition
Key Code
Error Enumeration,
String, and Condition
Recovery Procedure