User Guide

Ampex 1308910-01 A-11
Returned Sense Data Vendor-Specific ACL Condition Codes
0x04 0x55 0xA2 0x22
Hardware Error
AC_EMPTY_ON_GET
Hardware Error, Source Bin Empty
on Get
The CHS Failed to get the cartridge
from the source bin because the
mechanical hand could not grab the
cartridge (as if the source bin were
empty). The bin database had already
been checked, and the source bin
should have been full.
Initialize Element Status to audit
the storage bins and update their
status in the internal database.
Then Read Element Status to
check the contents of the source
bin from which you tried to
move a cartridge. If the bin is
full, there is a problem with the
CHS hardware. It may need
recalibration, or it may be
failing.
0x04 0x55 0xA3 0x23
Hardware Error
AC_FULL_ON_PUT
Hardware Error, Destination Bin
Full on Put
The CHS failed to put the cartridge into
the destination bin because the
mechanical hand hit an obstruction (as
if the destination bin were already full).
The bin database had already been
checked, and the destination bin should
have been empty.
0x04 0x55 0xBC 0x3C
Hardware Error
AC_ROBOT_ACCESS_FAILURE
Hardware Error, CHS Access
Failure
A CHS hardware failure occurred.
A SCSI reset or power reset may
bring the system back. If not,
contact Ampex Technical
Support.
0x04 0x55 0xBD 0x3D
Hardware Error
AC_ROBOT_ACCESS_REJECTED
Hardware Error, CHS Access
Rejected
The ACL is unable to execute CHS
movement commands.
0x04 0x55 0xBF 0x3F
Hardware Error
AC_ROBOT_HW_FAILURE
Hardware Error, CHS Mechanical
Failure
The CHS has been unable to complete a
request because of a mechanical failure.
The CHS failure code indicates the
cause of the error.
Check the CHS failure code
returned by aclGetStatus().
0x04 0x55 0xC1 0x41
Hardware Error
AC_SHARED_DB_ERROR
Hardware Error, Internal
Database Fault
A CHS hardware failure occurred.
Contact Ampex Technical
Support.
Table A-3. Vendor-Specific ACL Condition Codes (Continued)
ACL
Sense ASC ASCQ Condition
Key Code
Error Enumeration,
String, and Condition
Recovery Procedure