User Guide

Ampex 1308910-01 A-7
Returned Sense Data Vendor-Specific ACL Condition Codes
A.4 Vendor-Specific ACL Condition Codes
Table A.4 lists vendor-specific condition codes the ACL might report in the data returned for
aclGetStatus(). The table is arranged in alpha-numeric sequence, ordered as follows:
Sense Key
ASC/ASCQ
Condition Code
Note: DST 712 information is currently not available.
Table A-3. Vendor-Specific ACL Condition Codes
ACL
Sense ASC ASCQ Condition
Key Code
Error Enumeration,
String, and Condition
Recovery Procedure
0x00 0x00 0x00 0x00
No Sense
AC_NO_ERROR,
No Condition
Sense data not set.
Not Required.
0x01 0x55 0xBE 0x3E
Recovered Error
AC_ROBOT_ACCESS_WARNING
Recovered Error, CHS Access
Warning; No Action Required
Command completed with CHS
warning.
0x01 0x80 0x00 0x18
Recovered Error
AC_RBT_TALLY_WARNING
Recovered Error, CHS Tally
Warning; No Action Required
Command completed with CHS
warning.
0x02 0x04 0x01 0x27
Not Ready
AC_AUDIT_IN_PROGRESS
Not Ready, Audit in Progress
The CHS is performing an audit.
Wait for the audit to complete.
This can take up to 45 seconds
for an 812 ACL.
0x02 0x04 0x03 0x24
Not Ready
AC_NOT_READY
Not Ready, Initializing
The ACL Software is Initializing
Wait for initialization to
complete. This can take up to 20
seconds.
0x02 0x04 0x03 0x2E
Not Ready
AC_NOT_READY_DOOR
Not Ready, Door Open
A cabinet door is open. While the door
is open, CHS movements are disabled
for safety reasons. In addition, storage
bin status (empty or full) cannot be
reliably determined.
Close all doors (for an 812 ACL,
also reset the MDA POWER
switch). The ACL automatically
performs any recovery or
initialization procedures
required.