User Guide
Ampex 1308910-01 A-1
Returned Sense Data Error/Event Parameter Identification Codes
Appendix A
Returned Sense Data
A.1 Error/Event Parameter Identification Codes
Table A-1 lists the identification codes that the ACL might report in the Error/Event Log data
returned for acl_errlog_library. For some of these codes, additional integer values are
included to further describe the condition detected. In many cases, this additional information
is intended for Ampex factory personnel as interpretation of integer values requires a detailed
understanding of ACL internal operation.
Table A-1. Error/Event Parameter Identification Code Descriptions
Code Description Integer Interpretation
0x00 Invalid log code Invalid code number
0x01 Position to Element SCSI command N/A
0x02 Move Medium SCSI command
1
st
= source element address
2
nd
= destination element address
3
rd
= transport element address
0x03 Read Element Status SCSI command
1
st
= number of elements
2
nd
= element type
3
rd
= first address for this element type
0x04 Log sense page N/A
0x05 Log select page N/A
0x06 Request Sense SCSI command N/A
0x07 Inquiry SCSI command N/A
0x08 Rezero Unit SCSI command N/A
0x09 Mode Sense SCSI command N/A
0x0A Mode Select (6) SCSI command
1
st
= element page length
2
nd
= address of first element
0x0B Mode Select (10) SCSI command
1
st
= element page length
2
nd
= address of first element
0x0C Test Unit Ready SCSI command N/A
0x0D CHS mode set to off-line N/A
0x0E CHS mode set to on-line N/A