User Guide
A-24 Preliminary Draft Ampex 1308904-X4
Model No.
Running Head
CHS Failure, Error, and Warning Codes ACL Application Programmer’s Guide
ERROR MESSAGES (2XX, 4XX)
3001d (BB9h) Cannot load to an occupied drive elevator
3002d (BBAh) Cannot unload to an occupied elevator bin
3003d (BBBh) Illegal bin number for a load
3004d (BBCh) Illegal bin number for a move
3005d (BBDh) Illegal bin number for an audit
3006d (BBEh) Illegal bin number for an unload
3007d (BBFh) Previous command has not completed
3008d (BC0h) The abort command is not currently supported
3009d (BC1h) The read command is not currently supported
3010d (BC2h) The readall command is not currently supported
ATTENTION MESSAGES (2XX, 4XX)
4001d (FA1h) Bin audit procedure has conflicting data
4002d (FA2h) Cannot enable in-arm servo position mode
4003d (FA3h) Cannot enable out-arm servo position mode
4004d (FA4h) Cannot set in-arm position counter
4005d (FA5h) Cannot set out-arm position counter
4006d (FA6h) Cartridge failed to contact home switch during re-load
4007d (FA7h) Cartridge failed to reach final position during re-load
4008d (FA8h) Drive elevator feed control failed to enable inject sensor
4009d (FA9h) Drive timeout failed to clear load port sensor
4010d (FAAh) Drive timeout failed to enable load port sensor
4011d (FABh) Drive timeout re-load failed to enable home sensor
4012d (FACh) Drive timeout re-load failed to enable load port sensor
4013d (FADh) Elevator failed to move down during recovery
4014d (FAEh) Elevator failed to move up during recovery
4015d (FAFh) Elevator failed to position during re-load
4016d (FB0h) Elevator lower over travel sensor tripped
4017d (FB1h) Elevator mda safety shut off is disabled
Table A-5. CHS Failure, Error, and Warning Codes (Continued)
CHS Code Description