User Guide

Ampex 1308904-X4 Preliminary Draft A-11
ACL Application Programmer’s Guide Vendor-Specific ACL Condition Codes
06h 29h 00h 69h
Unit Attention
Power On or Unit Reset Condition
Indicates this is the first command
sent by the initiator after the ACL
completed a boot sequence.
The application software might
have to be re-initialized.
0Bh 55h B9h 39h
Aborted Command
CHS Failed on Put Command and
Restored System to Previous
Condition (8XX)
The ACL was executing a Move
command which involves getting a
cartridge from one location and
putting it in another. The get was
successful, but the put failed. The
ACL was able to restore the
cartridge to its original location and
the bin database is in the original
condition it was in before the Move
command was attempted.
Not required.
0Bh 55h BAh 3Ah
Aborted Command
CHS Failed on Put Command and
Was Unable to Restore System to
Previous Condition (8XX)
The ACL was executing a move
command which involves getting a
cartridge from one location and
putting it in another. The get was
successful, but the put failed. The
ACL was unable to restore the
cartridge to its original location and
the bin database is in a different
state than when the Move command
was initiated.
Read Element Status to determine
current element status.
0Bh 55h BBh 3Bh
Aborted Command
CHS Received a SCSI Abort
The ACL aborted the command in
response to a message received over
the SCSI bus.
Retry the command.
0Bh 5Ah 00h 2Ch
Aborted Command
Command Failure Because CHS is
Off-Line (2XX, 4XX)
Off-line operation was selected at
the front panel while the ACL was
executing a command.
Change mode to on-line using
front-panel message screen
buttons. The CHS will
automatically perform any
recovery or initialization
procedures required.
Table A-4. Vendor-Specific ACL Condition Codes (Continued)
ACL
Sense ASC ASCQ Condition
Key Code
Condition Reported Recovery Procedure