User Guide
A-6 Preliminary Draft Ampex 1308904-X4
Model No.
Running Head
Vendor-Specific ACL Condition Codes ACL Application Programmer’s Guide
A.4 Vendor-Specific ACL Condition Codes
Table A.4 lists vendor-specific condition codes the ACL might report in the data returned for
aclReqSense(), aclStatus(), and acl_status_library. The table is arranged in alpha-numeric
sequence, ordered as follows:
Sense Key
ASC/ASCQ
Condition Code
Table A-4. Vendor-Specific ACL Condition Codes
ACL
Sense ASC ASCQ Condition
Key Code
Condition Reported Recovery Procedure
00h 00h 00h 00h
No Sense
No error.
01h 55h BEh 3Eh
Recovered Error
Recovered Error
The CHS reported a warning about a
command that completed
successfully. The CHS Warning
Page will be appended with the
specific code for the warning.
Not required.
02h 04h 01h 27h
Not Ready
Unit Becoming Ready
The CHS is auditing the storage bins
so that the Read Element Status data
can be initialized.
Wait for the audit to complete.
This can take up to 45 seconds for
an 8XX ACL.
02h 04h 03h 24h
Not Ready
Unit Not Ready—The ACL
Software is Initializing
Wait for initialization to complete.
This can take up to 20 seconds.
02h 04h 03h 2Eh
Not Ready
Unit Not Ready—Door Open
A cabinet door is open. While the
door is open, CHS movements are
disabled for safety reasons. In
addition, storage bin status (empty
or full) cannot be reliably
determined.
Close all doors (for an 8XX ACL,
also reset the MDA POWER
switch). The ACL automatically
performs any recovery or
initialization procedures required.
02h 04h 03h 2Fh
Not Ready
Unit Not Ready—Manual Mode
(2XX, 4XX)
The ACL can be operated from its
front panel independently from the
host. While it is in manual mode, it
will not execute SCSI commands.
Change mode to on-line using
front-panel message screen
buttons.