User Guide
A-2 Preliminary Draft Ampex 1308904-X4
Model No.
Running Head
Error/Event Parameter Identification Codes ACL Application Programmer’s Guide
0Fh CHS door opened N/A
10h CHS door closed N/A
11h CHS command sent Command opcode
12h CHS command complete N/A
13h Unable to send CHS command Command opcode
14h CHS command complete with warning Command opcode
15h CHS command failure Command opcode
16h CHS command timeout Command opcode
17h CHS response Response code
18h
Bar code command sent to bar code
reader
Command opcode
19h Bar code data sent to CHS
1
st
= status
2
nd
= code
1Ah Unable to send bar code data to CHS N/A
1Bh
Internal command processor (ICP)
queue timeout
ICP state
1Ch ICP message queue error Software trace
1Dh ICP received bad message Message size
1Eh ICP received a new message ICP state
1Fh Launching new state machine N/A
20h New SCSI command received N/A
21h PSOS queue error Software trace
22h Move Volume SCSI command
1
st
= tape cartridge bar code ID
2
nd
= source element address
3
rd
= destination element address
4
th
= transport element address
23h Error getting bin data from database Error code
24h Error getting drive data from database Error code
25h Error getting tally data from database Error code
26h
Returning tape cartridge to source
storage bin
Bin number
Table A-1. Error/Event Parameter Identification Code Descriptions (Continued)
Code Description Integer Interpretation