Specifications

Ampac Technologies Pty Ltd
FireFinder
TM
Operators Manual
PAGE 25
DOC No:G0109WO1.doc DIR: L:\MANUALS DATE: 30/11/00 REVISION: 3
7
FireFinder
TM
Operation
7.1 The Control Panel
Fig21: The FireFinder
TM
Control Panel
1. ALARM (Red) - This LED will flash if any unacknowledged alarms are present on the system. If all the
alarms have been acknowledged it will light steady.
2. FAULT (Yellow) - This LED will light steady if there are any faults on the system, whether they are
loop faults, module faults, device faults etc.
3. ISOLATED (Yellow) - This LED will light steady if any detectors, devices or zones in the system have
been isolated.
4. EXTERNAL BELL ISOLATE (Yellow) - Pressing this button will isolate any bells connected to the fire
panel If the bell is isolated the LED just above the button will glow steady yellow. Pressing the button
again will de-isolate the bell.
5. WARNING SYS ISOLATE - Pressing this button will isolate the fire panel output to the Warning
System if it is connected to one. If the Warning System is isolated the LED just above the button will light
steady. Pressing the button again will de-isolate the Warning System output.
6. PREVIOUS - This key is used for scrolling backwards through alarms, faults, or isolates on the LCD.
7. NEXT - This key is used for scrolling forwards through alarms, faults, or isolates on the LCD.
8. ACKNOWLEDGE - Pressing this key will acknowledge an alarm currently displayed on the LCD. It will
also silence the panel buzzer, which sounds whenever there is an alarm (optional) or fault.
9. RESET - Pressing this key will reset the panel, clearing any acknowledged alarms and taking the LCD
display back to its default screen, unless there are any uncleared faults or isolated devices, these will
continue to be displayed.
10. ISOLATE - This key is used to isolate individual or groups of detectors, devices or zones.
11. POWER ON (Green) - This LED will light when the mains power is turned on.
12. PRE-ALARM (Yellow) - This LED will light when a sensor/detector is in the pre-alarm state.
WARNING SYS
ISOLATE
EXTERNAL BELL
ISOLATE
PREVIOUS NEXT
ACKNOWLEDGE
ISOLATERESET
WARNING
SYS FAULT
TEST MODE
SYSTEM FAULT
EARTH FAULT
AIF ACTIVE
AUX ALARM
PRE-ALARM
SUPPLY FAULT
POWER ON
ALARM
FAULT
ISOLATED
DE-ISOLATE
FAULT
OUTPUT ISOLATE
AUXILIARY
FAULT / ISOLATE
OUTPUT
DELAY ACTIVE
LOOP
ZONE
SENSOR
DISPLAY
TO
TUV
7
4
JKL
ABC
1
DEF
2
5
MNO
8
WXYZ
0
SPACE
3
GHI
6
PQRS
9
SYMB
ENTER
FUNCTION
MENU
CANCEL ENTRY
Finder
TM
FIREFIGHTER FACILITY
Fire
1. ALARM LED
2. FAULT LED
3. ISOLATED LED
4. EXTERNAL BELL ISOLATE
5. WARNING SYSTEM ISOLATE
20. DE-ISOLATE
21. FAULT OUTPUT ISOLATE
22. AUXILARY FAULT/ISOLATE
23. OUTPUT DELAY ACTIVE
24.LOOP
25. SENSOR
26. ZONE
27. DISPLAY 29. TO 30. ENTER
28. THE ALPHA/NUMERIC KEYS
6. PREVIOUS
7. NEXT
8. ACKNOWLEDGE
9. RESET 10. ISOLATE
35. LCD DISPLAY
11. POWER ON (GREEN)
12. PRE-ALARM (YELLOW)
13. AUX ALARM (YELLOW)
14. AIF ACTIVE (YELLOW)
15. SUPPLY FAULT (YELLOW)
16. EARTH FAULT (YELLOW)
17. SYSTEM FAULT (YELLOW)
18. TEST MODE (YELLOW)
19. WARNING SYTEM FAULT
(YELLOW)
31. CANCAL ENTRY
33. DOUBLE ARROW KEYS
34. MENU / FUNCTION
32. SINGLE ARROW KEYS