TECHNICAL SPECIFICATIONS
Supply Voltage: 115 - 220 VAC, 50 - 60 Hz
Current Draw: 1 Amp. Max.
Fuse (1/4 * 1-1/4): Fast Blow 1 Amp.
Cable requirement:
LCD Alarm to Remote Sensor:
Important:
Cable: Belden # 8451 or equivalent. #22 gauge shielded, twisted pair. (For multiple
sensors a multi-conductor twisted pair, shielded cable should be used).
Distance: Maximum 100 ft [30.5 m]
Signal: 30 VDC - 1.0 Amps.
60 VDC - 0.3 Amps.
125 VAC - 0.5 Amps.
LCD Alarm to Master:
Distance: Maximum 10,000 ft [3,000 m]
Cable: Minimum #22 gauge wire
Signal: 5 VDC - 5.0 Amps.
LCD Generic Alarm:
Output: Dry Contacts NC, open on Alarm.
Rating: 30 VDC - 1.0 Amps.
60 VDC - 0.3 Amps.
125 VAC - 0.5 Amps.