6. THE INDEXER CLAMP FEET PRESSURE ADJUSTMENT
1. First place the material under the left clamp foot.
2. Press the . Pull the clamped material and check if the material is held well.
3. Do the same with the right clamp foot.
4. If the pressure is not the same on both clamp feet, follow the below mentioned steps:
The left clamp foot holds the material more than the right one
a) press the left clamp foot ➊ by hand down to the clamp mat.
b) move the right clamp foot ➋ closer to the clamp mat by loosing the screw ➌ on the
right clamp foot
c) tighten the screw ➌ and release the left clamp foot by hand ➊
The left clamp foot holds the material less than the right one
a) press the left clamp foot by hand down to the clamp mat.
b) move the right clamp foot back from the clamp mat by loosing the screw on the
right clamp foot
c) tighten the screw and release the left clamp foot by hand
Check the correction of the adjustment according to the points 1-4.
NOTE: Since the clamp cylinder is closer to the right clamp foot, it is necessary to set the stronger pressure
on the left clamp foot.