F - SLEEVE INDEXER
4. ADJUSTMENT FOR ANGLE BUTTONHOLES
First check whether the indexer clamp feet arm is in the position of 90° against of the casting of the bedplate
. If it is not, loosen the screw and move the clamp feet arm into the required position. Tighten the screw.
NOTE: Switch off the air pressure supply before making this adjustment. Make sure that indexer clamp
feet are in the position for cross movement of the material - see F3, point 1 (page 1-50).
The clamp feet angle is ensured by the air pneumatic cylinder . It is necessary to regulate the air flow
coming into the cylinder to make sure the swivelling works well. T
oo much airflow and the movement
becomes rough. To make ascertain smooth movement of the angling mechanism, adjust as follows:
1. Remove the indexer cover .
2. Loosen the locking nut and turn the regulator clockwise. Ensure the position with
the nut.
3. Loosen the screw and move the nut to the left from the locking lever in arrow direction.
Tighten the screw.
4. Connect the air supply and turn the main power switch on
by turning clockwise to
the I position.
5. By pressing the key, check the indexer clamp feet smooth movement.