E - MACHINE ADJUSTMENTS
17. ADJUSTMENT OF THE STOPPING SENSOR POSITION
Follow the below described steps to set the position of the sensor.
1. Put machine in the service mode (see E-3).
2. Turn the handwheel counter clockwise until the machine is in the position for sewing the second
bar. The stop disk finger must be perpendicular to the sensor .
3. Loosen the screws and move the sensor bracket to the right. Tighten the screws .
4. Loosen M3 screw and adjust the sensor position so that the stop disk finger is in the center
of the sensor mark . The red LED lights up on the sensor.
5. Tighten the M3 screw .
6. Return the machine head back to the working positon.
7. Push the key on the control panel and switch the machine to the working mode.
8. Connect the air tubes with the indexer clamp feet. Open the air supply.
9. Start the machine and check the correct stopping of the machine. The needle bar must stop in
the home (upper) position.