4. NEEDLE BAR
1. Needle bar crank position
Turn the handwheel and loosen the screw in the
needle bar crank . Turn the handwheel until the
needle bar reaches the upper position. Pulley screw
on the main shaft should be in the same line with
screw. Tighten the screw .
NOTE: The needle bar should be in the top dead center
position when the screw is at 12 o‘clock. To check,
turn the handwheel clockwise and counter clockwise.
The needle bar must move downward in either
direction. The needle makes its first stroke into the
right side of the throat plate.
2. The needle bar height adjustment
Adjust the needle bar height to 16 mm (5/8“) from
the surface of the throat plate to the upper edge
of the needle eye. Use height gauge .
Loosen the set screw and move the needle bar up
or down as necessary.
E - MACHINE ADJUSTMENTS