Service manual
S-4000 ISBH+I Omron
Revised 11/2009
e-mail: service@amfreece.cz; parts@amfreece.cz; website: www.amfreece.com
Phone: +420 582 309 146 (Service), +420 582 309 286 (Spare Parts); Fax: +420 582 360 606
1-9
B - MACHINE ASSEMBLY
customer. These connectors are not included in the accessories. A tubing clamp ➌ is provided.
NOTE: Parts ➊, ➋, ➎, ➏ are included in Extra Parts - see 3-69.
2. After air connection check the set air pressure on the dial of the regulator. It should be in range
0.5 - 0.6 MPa. The green pointer ➐ indicates the lowest working air pressure 0.5 MPa, which is set
from the manufacturer on the regulator ➑. If the air pressure is lower than 0.5 Mpa after connecting
the machine to the power supply „Low Pressure“ message appears on the control panel display. To
adjust the working pressure, loosen the regulator cap lock ➓ and turn the regulator cap clockwise to
increase the pressure. Push the regulator cap ➓ down.
3. Power supply must be 208 to 230 volts 1 phase, 50 or 60 hertz. Receptacle plug must meet
requirements of IEC standard 364-4-41, its circuit breaker must be minimal 10A with characteristic
C according to the EN 60947-2 (or 16A with characteristic B). No other devices must not be
connected to the circuit breaker of the socker. The hand wheel must turn counter clockwise.
The machine is equipped with a filters which contain capacitors which generate an high
frequency leakage current. In order to prevent nuisance tripping, residual current protection
dev
ice must be protected against these high frequency currents: this is the case for industrial
residual current device (example „S“ type).
3. POWER AND AIR CONNECTION
1. The machine is equipped with a quick coupler ➍
required with connector for inner ∅ of the tube 10.
The connector for inner ∅ of the tube 8 is not supplied
with the machine, a customer has to order it.
The manufacturer recommends to use connector ➏ for
who requires to connect the tube with connector NPT.
If a customer needs to use a shut off valve ➊, which
allows fast releasing of the air from the circuit, he must
order it.
A variety of connectors
➋➋
➋➋
➋ can be used separately or in
combination to adapt to the available input supply hose.
It depends on type of the tube which is used by a