Service manual
Table Of Contents
- MODEL S 4000 CAED Omron
- WARRANTY
- WARRANTY REGISTRATION CARD
- TABLE OF CONTENTS
- A-INTRODUCTION
- B-MACHINE ASSEMBLY
- C-PROPER APLICATION
- D-MACHINE CONTROLS
- E-MACHINE ADJUSTMENTS
- G-PNEUMATIC DIAGRAM
- F-MACHINE MAINTENANCE
- 1.MACHINE HOME POSITION
- 2.ADJUSTMENT OF THE SHIFTER
- 3.PRINCIPLES FOR MACHINE ADJUSTMENT
- 4.NEEDLE BAR
- 5.BITE
- 6.FEEDING
- 7.CLUTCH
- 8.STITCH DENSITY
- 9.LOOPERS ADJUSTMENT
- 10.HOME POSITION OF THE CLAMP PLATE
- 11.CLAMP PLATE ADJUSTMENT
- 12.TRIMMING MECHANISM ADJUSTMENT
- 13.ADJUSTMENT OF THE CLAMP PLATE CHANGE-OVER
- 14.ADJUSTMENT OF MACHINE HEAD CLAMPING FOOT
- 15.THREAD DRAW OFF
- 16.THREAD TENSION
- 17.THREAD TRIMMING
- 18.CUTS-OFF BLOW OFF
- 19.THREAD BLOW OFF (SPECIAL ACCESSORY)
- 20.ADJUSTMENT OF STOP SENSOR POSITION
- 21.REPLACEMENT OF THE BELT
- 22.PROTECTION DURING VOLTAGE FLUCTUATION (SPECIAL ACCESSORY)
- 23.OPTICAL SENSOR-ADJUSTMENT
- H-ELECTRICAL DIAGRAM
- TROBLESHOOTING-TABLE OF CONTENTS

Released 10/2009
S-4000 CAED Omron
2-5
TROUBLESHOOTING
e-mail. serv
ice@amfreece.cz; parts@amfreece.cz; website: www.amfreece.com
Phones: +420 582 309 160 (Service), +420 582 309 286 (Spare Parts); Fax: +420 582 360 606
2. ERROR MESSAGES OF THE CONTROL PANEL DISPLAY
SYMPTOM
POSSIBLE CAUSE
PROBABLE SOLUTION
Low air pressure
Emergency stop, red LED
light is ON
Service mode
Hand valve of the regulator
switched off (if assembled)
The air pressure in the air
supply piping below 0.5 MPa
Emergency Stop button is
switched on
The machine is in the service
mode, motor is disconnected
Open the hand valve
Increase the air pressure
Release the Emergency Stop
button and press F6 key on the
control panel
Press F6 key on the control
panel
3. ERROR MESSAGES OF THE SERVO
Power
supply
indicator
Alarm
indicator
(ALM)
PWR - Power supply indication:
INDICATOR STATUS
Lit green
Lit orange - Flashes at a 1
sec. intervals
Lit red
Voltage is good
Varning - i.e.:
- Exceeded power
- Exceeded feed back
- Default of inner fan
Alarm - default
ALM - Default indication (Alarm indicator):
in case default appears, the indicator is switched on.