Service manual
Table Of Contents
- MODEL S 4000 CAED Omron
- WARRANTY
- WARRANTY REGISTRATION CARD
- TABLE OF CONTENTS
- A-INTRODUCTION
- B-MACHINE ASSEMBLY
- C-PROPER APLICATION
- D-MACHINE CONTROLS
- E-MACHINE ADJUSTMENTS
- G-PNEUMATIC DIAGRAM
- F-MACHINE MAINTENANCE
- 1.MACHINE HOME POSITION
- 2.ADJUSTMENT OF THE SHIFTER
- 3.PRINCIPLES FOR MACHINE ADJUSTMENT
- 4.NEEDLE BAR
- 5.BITE
- 6.FEEDING
- 7.CLUTCH
- 8.STITCH DENSITY
- 9.LOOPERS ADJUSTMENT
- 10.HOME POSITION OF THE CLAMP PLATE
- 11.CLAMP PLATE ADJUSTMENT
- 12.TRIMMING MECHANISM ADJUSTMENT
- 13.ADJUSTMENT OF THE CLAMP PLATE CHANGE-OVER
- 14.ADJUSTMENT OF MACHINE HEAD CLAMPING FOOT
- 15.THREAD DRAW OFF
- 16.THREAD TENSION
- 17.THREAD TRIMMING
- 18.CUTS-OFF BLOW OFF
- 19.THREAD BLOW OFF (SPECIAL ACCESSORY)
- 20.ADJUSTMENT OF STOP SENSOR POSITION
- 21.REPLACEMENT OF THE BELT
- 22.PROTECTION DURING VOLTAGE FLUCTUATION (SPECIAL ACCESSORY)
- 23.OPTICAL SENSOR-ADJUSTMENT
- H-ELECTRICAL DIAGRAM
- TROBLESHOOTING-TABLE OF CONTENTS

S-4000 CAED Omron
e-mail: service@amfreece.cz; parts@amfreece.cz; website: www.amfreece.com
Phones: +420 582 309 146 (Service), +420 582 309 286 (Spare Parts); Fax: +420 582 360 606
Released 10/2009
2-4
TROUBLESHOOTING
SYMPTOM
POSSIBLE CAUSE
PROBABLE SOLUTION
Thread not trimmed at the
end of the cycle
The fabric is not cut at the
end of the cycle
Sewing motor turns, machine
does not sew
Machine sews continually,
does not stop
Zero pressure on regulator
Low air pressure
Trimming knife damaged
Low air pressure at trimming
cylinder
Incorrect loopers timing
Incorrect setting of trimming delay
Trimming length incorrectly set
The trimming knife is damaged
The edge of the stitching plate is
damaged
Low pressure in the cylinder
The trimming mechanism to cut
fabric adjusted incorrectly
Belt broken or loose
Stopping sensor adjusted
incorrectly
Shut off valve closed
Filter element dirty
Air fitting or tubing obstruction
Replace
Check supply pressure
See section E9
Change Trim delay parameter-D4
Change Trim time parameter-D4
Re-sharpen or replace with
a new one
Re-sharpen or replace with
a new one
Check the supply pressure
Check with the instructions provided
in Section E12
See section E21 for changing
See section E20 for correct position
adjustment
Open the shut off valve
Change the filter element
Check supply guides