Service manual

Table Of Contents
S-4000 CAED Omron
1-54
Revised 10/2009
e-mail: service@amfreece.cz; parts@amfreece.cz; website: www.amfreece.com
Phones: +420 582 309 146 (Service), +420 582 309 286 (Spare Parts); Fax: +420 582 360 606
H - ELECTRICAL DIAGRAM
OUTER
WIRING SYSTEM
MACHINE
WIRING SYSTEM
FLEXIBLE SUPPLY
MAIN SWITCH
(see CSN EN60204-1
seg. 5.3.2. - d)
MACHINE HEAD
MACHINE BASE
MACHINE STAND
OUTER CLAMP FOR BALANCING
POTENTIAL DIFFERENCE
EARTHING PLACES:
1 - control switchboard earthing
2 - control switchboard doors earthing
3 - GS1 source earthing
4 - minus pol secondary earthing
5 - U1 servoamplifier earthing
6 - Z2 filter earthing
7 - S1 servomotor earthing
8 - PLC FX1 earthing
9 - panel earthing
PROTECTIVE INTER CONNECTION DIAGRAM
OF CONSTRUCTION UNITS
FOR s-4000 BUTTENHOLE MACHINE
1N+PE 230V AC 50-60 Hz
ELECTRIC CURRENT SAFETY PROTECTION ACC.
CSN EN 61140:
BASIC PROTECTION: COVERS, INSULATION
PROTECTION DURING FAILURE: MAIN SUPPLY DISCONNECTION
PE CLAMP
PROTECTION CONNECTION WITH 1,5 mm WIRE
GREEN-YELLOW COLOUR
CONNECTION TEST ACCORDING CSN EN 60204-1 seg. 19.2
MACHINE CONNECTING CLAMP
FIRST INLET FILTER
CONTROL SWITCHBOARD