E - MACHINE ADJUSTMENTS
Loosen the holder of the optical sensor by loosing the screew M4 and adjust it in such way so that the ray of
the optical sensor projected by the sensor meets the glass eye in throat plate and returns back to sensor. The
sensor is switched on. After adjusting the sensor, tighthen the screws on holder. In case the fabric is put in
front of the glass eye for example, the control light of sensor is switched off.
To adjust the sensitiv
ity of the sensor, use the control element on sensor. To decrease the sensitivity, turn this
element into the left until the sensor light starts blinking. Then turn the element back until the light stops
blinking. It is also possible to check the signal from sensor in output tests, see section D5.
Caution! In order to ensure correct function of the sensor, keep the sensor eye clean, especially from
lubrication.
23. OPTICAL SENSOR - ADJUSTMENT
Screw M4
Fiber
Sensor optic
Fiber optic signal
Glass eye
Throat plate