Service manual
Table Of Contents
- MODEL S 4000 CAED Omron
- WARRANTY
- WARRANTY REGISTRATION CARD
- TABLE OF CONTENTS
- A-INTRODUCTION
- B-MACHINE ASSEMBLY
- C-PROPER APLICATION
- D-MACHINE CONTROLS
- E-MACHINE ADJUSTMENTS
- G-PNEUMATIC DIAGRAM
- F-MACHINE MAINTENANCE
- 1.MACHINE HOME POSITION
- 2.ADJUSTMENT OF THE SHIFTER
- 3.PRINCIPLES FOR MACHINE ADJUSTMENT
- 4.NEEDLE BAR
- 5.BITE
- 6.FEEDING
- 7.CLUTCH
- 8.STITCH DENSITY
- 9.LOOPERS ADJUSTMENT
- 10.HOME POSITION OF THE CLAMP PLATE
- 11.CLAMP PLATE ADJUSTMENT
- 12.TRIMMING MECHANISM ADJUSTMENT
- 13.ADJUSTMENT OF THE CLAMP PLATE CHANGE-OVER
- 14.ADJUSTMENT OF MACHINE HEAD CLAMPING FOOT
- 15.THREAD DRAW OFF
- 16.THREAD TENSION
- 17.THREAD TRIMMING
- 18.CUTS-OFF BLOW OFF
- 19.THREAD BLOW OFF (SPECIAL ACCESSORY)
- 20.ADJUSTMENT OF STOP SENSOR POSITION
- 21.REPLACEMENT OF THE BELT
- 22.PROTECTION DURING VOLTAGE FLUCTUATION (SPECIAL ACCESSORY)
- 23.OPTICAL SENSOR-ADJUSTMENT
- H-ELECTRICAL DIAGRAM
- TROBLESHOOTING-TABLE OF CONTENTS

S-4000 CAED Omron
1-41
Revised 10/2009
e-mail: service@amfreece.cz; parts@amfreece.cz; website: www.amfreece.com
Phone: +420 582 309 146 (Service), +420 582 309 286 (Spare Parts); Fax: +420 582 360 606
E - MACHINE ADJUSTMENTS
22. PROTECTION DURING VOLTAGE FLUCTUATION (SPECIAL ACCESSORY)
The special accessory, guard voltage relay HRN-35 (VC1), is placed in the machine control box. It is pre-set
and sealed from the manufacturer. If the supply voltage runs within the required range, the Led light Un on
the relay lits green. Once the upper limit is exceeded (255V), the LED lights lits red
. If the bottom limit
is exceeded (185V) the green LED light turns out and the red LED light comes on. The control LED
lights turn out if the voltage goes back to the required values. The delay of the relay activation is set up to a
minimal value.
Exceeding upper supply voltage limit (255V)
a) Turning the switch on
, red LED light is on . Supply voltage for electronics is cut off, the
display is not illuminated, the machine cannot be turned on.
b) If the limit values of the supply voltage are exceeded during sewing, the machine
automatically switches off in order to prevent control electronics from damaging. Once
the value gets back to normal (185V - 255V), the machine can be switched on in a
standard way (see section C1).
Exceeding bottom supply voltage limit (185V)
a) Once the voltage drops below the bottom limit, the display shows the „LOW VOLTAGE“ message and
the machine cannot be switched on.
b) If the supply voltage drops during sewing, the machine automatically stops and the display shows the
„LOW VOLTAGE“.message.
Once the voltage reaches the value 185V the machine can be switched on in a standard way (see
section C1).