11. CLAMP PLATE ADJUSTMENT
1. If the distance between the clamp plate cover and the throatplate edge is too large, proceed as
instructed in items 2 and 3. Recommended distance – 0,2 mm.
2. Loosen the nut in the lever groove .
3. Insert the gap gauge 0,2mm into the gap between the clamp plate cover and the throatplate edge .
Move the clamp plate onto the gauge and secure the position by tightening the nut .
12. TRIMMING MECHANISM ADJUSTMENT
If the mechanism does not trim properly, do the following:
* Disconnect the air supply, close the clamp feet and move the clamp plate to the left from the shear edge.
1. Check the shear knife and throatplate
edges . If they are damaged, they can be
sharpened or replaced with new parts.
2. Puss the trimming mechanism from the top
by your hand and check whether the
shears slightly overlap along the shear
edge. If they do not overlap, loosen the
screw M4 and turn the studs . Secure
the position by tightening the screws M4.