Service manual

Table Of Contents
S-4000 CAED Omron
1-30
Revised 10/2009
e-mail: service@amfreece.cz; parts@amfreece.cz; website: www.amfreece.com
Phones: +420 582 309 146 (Service), +420 582 309 286 (Spare Parts); Fax: +420 582 360 606
E - MACHINE ADJUSTMENTS
9. LOOPERS ADJUSTMENT
Before the adjustment, follow the instructions below:
· Turn the hand wheel and see carefully the position of the connecting rod on both extreme
positions of the looper movable arm . Angle A and angle B should be even.
· If the angles are not even – loosen the hexagonal erection bolt and turn the eccentric
adjusting bolt nut as necessary. T
ighten the hexagonal erection bolt .
· Turn the hand wheel to set the needle bar to the upper dead centre.
· Check that the needle is straight.
· Tilt the head onto the support pin and check that the mark on the looper cam is on the left
side. If it is on the right side, take the cam out and turn. Place the machine head back to the
operation position.
· Remove the cover , disconnect pneumatic pipes from the clamping cylinder and take the
clamping assembly out. Remove the throatplate
, trimming hook cover and trimming
hook. Dismantle the holders with loopers.