Service manual

Table Of Contents
S-4000 CAED Omron
1-26
Revised 10/2009
e-mail: service@amfreece.cz; parts@amfreece.cz; website: www.amfreece.com
Phones: +420 582 309 146 (Service), +420 582 309 286 (Spare Parts); Fax: +420 582 360 606
E - MACHINE ADJUSTMENTS
5. BITE
Before setting up the bite, dismantle pulley cover Ë and head
cover Ê.
1. Bite cam
a) Check that the machine is in home position.
b) Tilt the machine head onto the support pin Ð .
If the adjustment is correct, the second setscrew
Ñ of the cam Ò (counter-clockwise) must fi
t
vertically onto the bedplate casting.
c) Preparatory adjustment of the bite is done by
tightening the setscrew Ñ of the cam Ò on the
shaft.
The needle Ó must travel even distance when
moving up and down from the up dead centre.
Bite
Needle
stroke
Needle upper position
ÓÓ
ÓÓ
Ó
ÊÊ
ÊÊ
Ê
ËË
ËË
Ë