Service manual
Table Of Contents
- MODEL S 4000 CAED Omron
- WARRANTY
- WARRANTY REGISTRATION CARD
- TABLE OF CONTENTS
- A-INTRODUCTION
- B-MACHINE ASSEMBLY
- C-PROPER APLICATION
- D-MACHINE CONTROLS
- E-MACHINE ADJUSTMENTS
- G-PNEUMATIC DIAGRAM
- F-MACHINE MAINTENANCE
- 1.MACHINE HOME POSITION
- 2.ADJUSTMENT OF THE SHIFTER
- 3.PRINCIPLES FOR MACHINE ADJUSTMENT
- 4.NEEDLE BAR
- 5.BITE
- 6.FEEDING
- 7.CLUTCH
- 8.STITCH DENSITY
- 9.LOOPERS ADJUSTMENT
- 10.HOME POSITION OF THE CLAMP PLATE
- 11.CLAMP PLATE ADJUSTMENT
- 12.TRIMMING MECHANISM ADJUSTMENT
- 13.ADJUSTMENT OF THE CLAMP PLATE CHANGE-OVER
- 14.ADJUSTMENT OF MACHINE HEAD CLAMPING FOOT
- 15.THREAD DRAW OFF
- 16.THREAD TENSION
- 17.THREAD TRIMMING
- 18.CUTS-OFF BLOW OFF
- 19.THREAD BLOW OFF (SPECIAL ACCESSORY)
- 20.ADJUSTMENT OF STOP SENSOR POSITION
- 21.REPLACEMENT OF THE BELT
- 22.PROTECTION DURING VOLTAGE FLUCTUATION (SPECIAL ACCESSORY)
- 23.OPTICAL SENSOR-ADJUSTMENT
- H-ELECTRICAL DIAGRAM
- TROBLESHOOTING-TABLE OF CONTENTS

S-4000 CAED Omron
1-25
Revised 10/2009
e-mail: service@amfreece.cz; parts@amfreece.cz; website: www.amfreece.com
Phone: +420 582 309 146 (Service), +420 582 309 286 (Spare Parts); Fax: +420 582 360 606
E - MACHINE ADJUSTMENTS
the first stitch direction
4. NEEDLE BAR
1. Position of the bell-shaped eccentric
Turn the hand wheel Î and loose the fastening screw Ê
1 in the bell-shaped eccentric Ë. Keep turning the hand
wheel until the needle bar reaches upper position.
Pulley screw Ì on the main shaft is on the same level
with the bearing cage screws Í Tighten the fasting
screw Ê.
NOTE: In order to check this dev
ice (home position),
turn the hand wheel forward and backward. The needle
bar must go down, not up. The needle Ó must start
sewing in the direction of the arrow – see the picture.
After the adjustment of the eccentric, check the position
of loopers and main shaft with the upper shaft. (See
loopers adjustment).
2. Setting up the height of the needle bar
With the machine in home position, set up the needle bar
Ò with the gauge Ï to the height of 16 mm (5/8“) from
the top of the throatplate Ð to the low edge of the
needle eye.
Loosen the setscrew Ñ and move the needle bar up or
down as necessary.