Service manual
Table Of Contents
- MODEL S 4000 CAED Omron
- WARRANTY
- WARRANTY REGISTRATION CARD
- TABLE OF CONTENTS
- A-INTRODUCTION
- B-MACHINE ASSEMBLY
- C-PROPER APLICATION
- D-MACHINE CONTROLS
- E-MACHINE ADJUSTMENTS
- G-PNEUMATIC DIAGRAM
- F-MACHINE MAINTENANCE
- 1.MACHINE HOME POSITION
- 2.ADJUSTMENT OF THE SHIFTER
- 3.PRINCIPLES FOR MACHINE ADJUSTMENT
- 4.NEEDLE BAR
- 5.BITE
- 6.FEEDING
- 7.CLUTCH
- 8.STITCH DENSITY
- 9.LOOPERS ADJUSTMENT
- 10.HOME POSITION OF THE CLAMP PLATE
- 11.CLAMP PLATE ADJUSTMENT
- 12.TRIMMING MECHANISM ADJUSTMENT
- 13.ADJUSTMENT OF THE CLAMP PLATE CHANGE-OVER
- 14.ADJUSTMENT OF MACHINE HEAD CLAMPING FOOT
- 15.THREAD DRAW OFF
- 16.THREAD TENSION
- 17.THREAD TRIMMING
- 18.CUTS-OFF BLOW OFF
- 19.THREAD BLOW OFF (SPECIAL ACCESSORY)
- 20.ADJUSTMENT OF STOP SENSOR POSITION
- 21.REPLACEMENT OF THE BELT
- 22.PROTECTION DURING VOLTAGE FLUCTUATION (SPECIAL ACCESSORY)
- 23.OPTICAL SENSOR-ADJUSTMENT
- H-ELECTRICAL DIAGRAM
- TROBLESHOOTING-TABLE OF CONTENTS

S-4000 CAED Omron
1-22
Revised 10/2009
e-mail: service@amfreece.cz; parts@amfreece.cz; website: www.amfreece.com
Phones: +420 582 309 146 (Service), +420 582 309 286 (Spare Parts); Fax: +420 582 360 606
D - MACHINE CONTROL
12.
Knife
OffTrim
Off
- To activate thread trimming, press key á
Knife
OffTrim
Off
,
confirm ➡
Knife
Trim
Off
On
. This parameter tests the YV3
valve.
13.
Shift
Off
- To activate clamping plate shift, press key á
Shift
On
, confirm ➡
Shift
On
and
the clamp plate is shifted. This parameter tests the valve YV5 valve.
14.
Direction
Mater. Blow
Off
Off
- To activate shifter press the key á
Direction
Mater. Blow
Off
On
,
confirm ➡
Direction
Mater. Blow
Off
On
and the cylinder for shifter is
moved. This parameter tests the YV6 valve.
15.
Direction
Mater. Blow
On
Off
- To activate this press the key ➡
Direction
Mater. Blow
On
On
, confirm
➡
Direction
Mater. Blow
On
On
. The clamping foot starts blowing air.
This parameter tests the YV7.
16.
Thread Blow
Off
- To activate the thread blow off press the key ➡
Thread Blow
On
. Confirm ➡
Thread Blow
On
, the
air starts blowing. This parameter tests the YV8 valve (if this valve is
assembled).
6. PROGRAM VERSION
Ready
1239
á Press the key á á á
PLC: 21.01
NT2S: 21.01
á á á
F
2
á
Ready