Service manual

Table Of Contents
S-4000 CAED Omron
1-21
Revised 10/2009
e-mail: service@amfreece.cz; parts@amfreece.cz; website: www.amfreece.com
Phone: +420 582 309 146 (Service), +420 582 309 286 (Spare Parts); Fax: +420 582 360 606
D - MACHINE CONTROLS
6.
Em Stop
Clamp Button
On
O ff
- After pressing button,
Em Stop
Clamp Button
Off
O ff
appears on the
display. After releasing the button
appears on the display. This parameter checks
the switch SA1.
7.
Em stop
Clamp button
On
Off
- By pressing the clamps
button
Em stop
Clamp button
On
On
appears on the display and clamps close. By pressing this button once
more, the clamps are lifted. This parameter checks the switch SB3.
8.
Motor ready
On
- If
Motor Ready
Off
appears on the display, go to the section
“Troubleshooting”.
9.
CAED sensor
On
- Correction of the sensor position. If the fabric is inserted,
CAED sensor
Off
key on the last inputs test screen
Off
Output tests
Clamps
appears on display. By pressing k
ey you
choose the row you need to change. The changed output is signalized by blinking. Press
to get to the
following screen. Press
F
2
to go back in tests. Press key to get back to the main screen.
10.
Output tests
Clamps
Off
- To activate clamps, press key
Output tests
Clamps
On
, confirm
á
Output tests
Clamps
On
clamps close. To lift the clamps, press
key á
Off
Output tests
Clamps
, confirm á
Output tests
OffClamps
and clamps are lifted. This parameter tests the
YV2 value.
11.
Knife
Trim Off
Off
- To activate the cutting lever and draw off, press á
Knife
Trim Off
Off
, confirm
Knife
Trim Off
On
.
Cutting lever moves down. This parameter tests the YV1 valve.
Display