Service manual

Table Of Contents
S-4000 CAED Omron
1-19
Revised 10/2009
e-mail: service@amfreece.cz; parts@amfreece.cz; website: www.amfreece.com
Phone: +420 582 309 146 (Service), +420 582 309 286 (Spare Parts); Fax: +420 582 360 606
D - MACHINE CONTROLS
10.
Cycle delay
(500-2500 ms)
500
- setting the delay between the sewing cycles. Cycling parameter must be
activated. It is possible to set it in range 500-2500 ms.
11.
Cycling
(yes/no)
no
- activation of the machine cycling. It is possible to set Yes / No.
12.
Pedal
(1step/2steps)
2steps
- setting the foot pedal position for sewing start. Possible setting 1 step / 2
steps.
13.
Double sew
(1, 2 = 1 or 2, 3 = 2)
1
- setting the number of cycle repeat. It is possible to set 1, 2 = 1 or 2, 3 =
2 = 1 or 2. When “2” is set, 2 cycle repeat are selected by holding the
pedal while sewing.
14.
Lcount
1239
Count Rst
No
- total cycles counter.
15.
Lcount
Count Rst
Yes
1239
- daily counter restart = set “yes” to restart.
16.
Mater. blow
(1-100 x 10ms)
40
- setting the air blow timming of cut-off material. Range 10-1000ms.
17.
Direction
(0-30 stitches)
0
- Setting of number of stitches sewn over the fabric/garment edge. Range
0-30 stitches. This range is necessary to adjust according to the
mechanically set sewing density and electronically set sewing speed.
18.
Optical sens Yes
(Yes/No)
- optical sensor function activation (Yes/No).
19.
Thread blow
(1-100 x 10ms)
30
- setting the thread blow timming. (If this dev
ice is installed on the
machine.) Range 10-1000ms.
20.
Shift time
(3-9 x 100ms)
4
- setting the clamping plate shift time. Range 300-900ms.
To return to the main screen, press key
Ready
1239
.
Display
4.1. Quick access into parameters used most often
- Maximal sewing speed. Can be set up within the range of 1000 –3800 stitches per
minute
-
Number of rows to be sewn. Possible to set
1, 2 = 1 or 2, 3 = 2.
Double sew
(1, 2=1 or 2, 3=2)
1