Service manual
Table Of Contents
- MODEL S 4000 CAED Omron
- WARRANTY
- WARRANTY REGISTRATION CARD
- TABLE OF CONTENTS
- A-INTRODUCTION
- B-MACHINE ASSEMBLY
- C-PROPER APLICATION
- D-MACHINE CONTROLS
- E-MACHINE ADJUSTMENTS
- G-PNEUMATIC DIAGRAM
- F-MACHINE MAINTENANCE
- 1.MACHINE HOME POSITION
- 2.ADJUSTMENT OF THE SHIFTER
- 3.PRINCIPLES FOR MACHINE ADJUSTMENT
- 4.NEEDLE BAR
- 5.BITE
- 6.FEEDING
- 7.CLUTCH
- 8.STITCH DENSITY
- 9.LOOPERS ADJUSTMENT
- 10.HOME POSITION OF THE CLAMP PLATE
- 11.CLAMP PLATE ADJUSTMENT
- 12.TRIMMING MECHANISM ADJUSTMENT
- 13.ADJUSTMENT OF THE CLAMP PLATE CHANGE-OVER
- 14.ADJUSTMENT OF MACHINE HEAD CLAMPING FOOT
- 15.THREAD DRAW OFF
- 16.THREAD TENSION
- 17.THREAD TRIMMING
- 18.CUTS-OFF BLOW OFF
- 19.THREAD BLOW OFF (SPECIAL ACCESSORY)
- 20.ADJUSTMENT OF STOP SENSOR POSITION
- 21.REPLACEMENT OF THE BELT
- 22.PROTECTION DURING VOLTAGE FLUCTUATION (SPECIAL ACCESSORY)
- 23.OPTICAL SENSOR-ADJUSTMENT
- H-ELECTRICAL DIAGRAM
- TROBLESHOOTING-TABLE OF CONTENTS

S-4000 CAED Omron
1-18
Revised 10/2009
e-mail: service@amfreece.cz; parts@amfreece.cz; website: www.amfreece.com
Phones: +420 582 309 146 (Service), +420 582 309 286 (Spare Parts); Fax: +420 582 360 606
D - MACHINE CONTROLS
Display Press Display Press
1.
- maximal speed. Range 1000-3800 spm.
2.
Slow stitch
(0-3)
0
- selecting the number of stitches in slow start. Range 0-3.
3.
Slow speed
(500-1000 rpm)
1000
- setting the slow start speed at the beginning of the sewing cycle. Range
500-1000 rpm.
4.
Ndl up pos
(0-600)
320
- correction of the needle bar upper position. Range 0 - 600 imp.
5.
Knife delay
(60-135 ms)
120
- setting the knife/draw-off delay. It is possible to set it in range 60-135
ms.
6.
Knife time
(30-200 ms)
100
- setting the timing of the knife/draw-off activation. It is possible to set it
in range 30-200 ms.
7.
Trim delay
(145-200 ms)
150
- setting the trim delay. It is possible to set it in range 145 - 200 ms.
8.
Trim time
(30-60 ms)
50
- setting the timing of trim activation. It is possible to set in range 30 - 60
ms.
9.
Clamp Delay
(0-100 ms)
50
- setting the clamp opening delay at the end of cycle.
It is possible to set in range 0-100 ms.
Display
Example: To change the sewing speed from 2000 to 3450
(3x)
(4x)
(5x)
á á
á
á
á
á
á
á
á
á
á
á