Service manual

S-4000 BH Omron
1-45
Released 05/2010
e-mail: service@amfreece.cz; parts@amfreece.cz; website: www.amfreece.com
Phone: +420 582 309 286; Fax: +420 582 360 606
2. The correct position of the tension mechanism
a) remove the tension assembly from the shaft
b) check if the distance between the stud slot edge and the pin is 3.5 mm If incorrect, it is
necessary to adjust the
position on the pin.
c) remove the pulley cover
and the head cover to
obtain a good access for
this adjustment. Switch
off the air supply.
d) disconnect the air tube
from the cylinder.
e) loosen the nut and
turn the cylinder as
necessary.
Turning clockwise
the pin is extended.
Tighten the nut when
the correct measurement is obtained.
f) connect the air tube to the cylinder, open the air supply and install the covers.
3. Regulation of the tension discs opening
If the last stitch is not tightened, follow the below mentioned steps:
a) loosen the locking nut on the speed controller
b) To obtain better tightening of the last stitch, tighten screw and lock the nut securely.
E - MACHINE ADJUSTMENTS