D - MACHINE CONTROLS
Display Press Display Press
(3x)
(4x)
(5x)
á
á
á
á
á
á
á
á
á
á
á
á
Example:
To change the sewing speed from 2000 to 3450
1. - setting the maximum speed.
Range 1000-3800 spm.
2.
Slow stitch
(0-3)
0
- selecting the number of stitches in slow start.
Range 0-3.
3.
Slow Speed
(500-1000spm)
1000
- setting the slow start speed at the beginning of the sewing cycle.
Range 500-1000 spm.
4.
Ndl up pos
(0-600)
320
- correction of the needle bar upper position.
Range 0 - 600 imp.
5.
Knife pos.
(-200 - +200)
0
- correction pozice průseku nože.
Range +200.
6.
Knife time
(30-200 ms)
100
- setting the knife cutting time.
Range 30 - 200 ms.
7.
Trim delay
(145-200 ms)
150
- setting the delay of the trimming
Range 145 - 200 ms.
8.
Trim time
(30-60 ms)
50
- setting the trimming time.
Range 30 - 60 ms.
9.
Clamp Delay
(0-100 ms)
50
- setting the delay of clamp feet opening at the end of a sewing cycle.
Range 0 - 100 ms.
Display