SYMPTOM POSSIBLE CAUSE PROBABLE SOLUTION
TROUBLESHOOTING
Two buttonhole lenght settings error in
indexer program.
Indexer total buttonhole length setting
error.
Indexer Buttonhole parameters setting
error.
Adjust the buttonhole lenght as to be
in range 7-16 mm.
Adjust the buttonhole lenghts
according the indexer sewing range.
Check the parameters for Buttonhole
marked Err.
E-60
E-61
E-99
Moveable support plate did
not move into required position.
Wait until the moveable support plate
moves to relevant position.
Emergency stop button.
Release the Emergency Stop button.
ACL-LPE eye cutting length
parameter error.
ACL-LP lapel cutting parameters
error.
ACL-LP lapel cutting lenght
parameter error.
Check the eye cutting length as to be
longer then eye length and shorter
than buttonhole length
Check the lapel cutting length and
position according to moveable
support plate range of machine type.
Check the lapel cutting length
according to moveable support plate
range of machine type