Service manual
Table Of Contents
- MODEL S 105
- LIMITED WARRANTY ON NEW AMF REECE EQUIPMENT
- WARRANTY REGISTRATION CARD
- TABLE OF CONTENTS
- A-INTRODUCTION
- B-MACHINE INSTALATION
- C-CORRECT USAGE
- 1.SEWING A BUTTONHOLE
- 2.NEEDLE EXCHANGE
- 3.THREADING THE MACHINE
- 4.PRINCIPLES OF SEWING
- 5.MACHINE DESCRIPTION AND ITS FUNCTIONS
- 6.CHANGING SEAMING WIDTH
- 7.STITCH DENSITY ADJUSTMENT
- 8.STITCHING LENGHT AND FLYBAR ADJUSTMENT
- 9.CHANGING THE POSITION IF STITCH ROWS-GAPS FOR CUT
- 10-SETTING THE SPREAD OF CLAMP FEET
- D-MACHINE ADJUSTMENT
- 1.TABLE ADJUSTMENT
- 2.STOPPING MECHANISM
- 3.BRAKE ADJUSTMENT
- 4.NEEDLE BAR AND RACE ALIGNMENT
- 5.BUTTONHOLE SHAPE ADJUSTMENT
- 6.NEEDLE BAR HEIGHT
- 7.LOOPERS ADJUSTMENT
- 8.SPREADERS ADJUSTMENT
- 9.UPPER THREAD TRIMMING
- 10.UPPER THREAD TENSION
- 11.SEWING SWITCH LEVER
- 12.CUTTING MECHANISM ADJUSTMENT
- 13.ADJUSTMENT OF CLAMPING MECHANISM
- E-MAINTENANCE
- TROUBLESHOOTING

Revised 11/2010
E-mail: service@amfreece.cz; parts@amfreece.cz; website: www.amfreece.com
Phone: +420 582 309 286; Fax: +420 582 360 606
S-105
1-32
D - MACHINE ADJUSTMENT
7.1. Adjustment is done with clamping plates dismantled from the machine,
stitching plate and the upper thread trimming knife holder
Ê
Ê
Ê Ê
Ê removed.
Loosen the screw
ËË
ËË
Ë to remove it.
7.2. The loopers are adjusted correctly if their tips are in the centre of the
needle, when the needle lifts up of 2,9 mm from the bottom dead point.
It is suitable to do the adjustment in the moment when the blocking
lever is out of function, in the area of sewing. This position can be
reached by turning the left hand wheel until the block lever lifts up.
7.3. Adjust the distance of the left looper
Î Î
Î Î
Î from the needle after loosing
the screw
Ñ Ñ
Ñ Ñ
Ñ so that there is a gap 0,1-0,2mm between the
needle and the looper tip. Tighten the screw. Adjust the
same gap on the right looper
Ð Ð
Ð Ð
Ð when it goes along the
needle.
7.4. The needle bar can be lifted up from the bottom position in
the centre stitch by turning the hand wheel so that it is pos-
sible to stick in a gauge
Í Í
Í Í
Í with its higher end between the
surface plane for clamping plates and the end of the needle
bar. Once you loose the clip screw
ÌÌ
ÌÌ
Ì, move the tip of the
left looper
Î Î
Î Î
Î onto the needle axis
Ï Ï
Ï Ï
Ï and tighten the screw.
Turn the hand wheel until the right looper
ÐÐ
ÐÐ
Ð comes to the
needle centre. Side bite should be minimal, as per section C6.
The needle bar should be at the same height as at the left
looper – check with a gauge
ÍÍ
ÍÍ
Í.
WARNING: It is important to check that the gap between left (right) looper is the same in the side bite
when coming back as per 7.3. Different gap can be adjusted as per section D5. it is necessary to check the
distance of the loopers in 3 positions of the needle bar and the race. (1
st
row of stitches, eye tip, 2
nd
row of
stitches).
7. LOOPERS ADJUSTMENT
ÊÊ
Ê
Ê
Ê
ËË
ËË
Ë
0
,
1
-
0
,
2
m
m
ÎÎ
ÎÎ
Î
ÐÐ
ÐÐ
Ð
ÏÏ
Ï
Ï
Ï
ÏÏ
Ï
Ï
Ï
ÎÎ
ÎÎ
Î
ÌÌ
Ì
Ì
Ì
REECE 105
03-0279-1-000
2
,
9
m
m
19,1 mm
ÑÑ
Ñ