Service manual
S100
1-69
Revised 10/2005
e-mail: service@amfreece.cz ; parts@amfreece.cz ; website: www.amfreece.com
Phones: +420 582 309 146 (Service), +420 582 309 286 (Spare Parts); Fax: +420 582 360 606
G - MACHINE MAINTENANCE
4. The air regulator maintenance - for modification CT (S 100 - 033/035/036) only.
Maintenance of air regulator contains check of the condensate and
possible replacement of the filter pad . The lever of the condensate
inside of the desliming receptacle must be 10 mm below the lever of
the filter pad . Lower ring of the nut signalizes this height.
Open the bleeder screw , so that the condensate can flow out. Then
tighten the screw again.
With worse air flow:
Replace the filter pad after air supply stopping. Exhaust the
desliming receptacle by loosening the screw and unscrew the
desliming receptacle anti-clockwise. By unscrewing the nut loosen
the filter element place the new one and assemble the device in
reverse order.
5. Perform visual check of mechanism especially in area of sewing mechanism.
6. When the maintenance and checking is finished, close covers, put back the clamps plates and then
continue with work.
2. PERIODIC MAINTENANCE
WARNING ! Before making any machine maintenance, switch off the power switch (circuit breaker),
which will prevent the accidental start-up and possible operator injury.
Once a day (10 hours of operation) - cleaning of the sewing mechanism area
- remove the waste from the oil reservoir
once a week (80 hours of operation) - check the filter regulator and flow out the condensate CT
only
- visual check - external and internal mechanisms
- check the belts tension
- check lubrication of mechanisms
once a month (300 hours of operation) - check of the throat plate wear
- check the screw connection tightening
- check the clearance in sewing mechanism drive
- check the condition of the wiring
Recommended values of screw tightening (Nm):
0,8
2,0
4,0
7,0
16,0
30,0
54,0
M3
M4
M5
M6
M8
M10
M12
0,5
1,2
2,5
4,0
0,6
1,5
3,0
5,0
8,0
10,0
25,0