Specifications

11
Call ZOT at 1-800-525-8116 for more details
Diagnostic LED’s
Power: Indicates when the chassis has power
High Voltage Fault: Indicates when there is a short in the 115Volt
circuit
Low Voltage Fault: Indicates when there is a short in the 24Volt
circuit
Cycle: Lights when machine is in continuous cycle
1st – Ball – 2nd: Indicates whether the machine is on First or
Second ball
Sweep: Lights when button is depressed while operating a Sweep
Table: Lights when button is depressed while operating the Table
Pin: Lights when pin feed solenoid is energized to fill the table
L & K: Checks all the respot cell switches
Foul: Lights when the chassis receives a signal from the foul unit
Instruct: Lights when machine is on Instruct-O-Mat mode
Option Switch’s
Cycle: Allows the pinspotter to be cycled from the managers con-
trol when going from Instruct-O-Mat to Bowl
Instruct: Disables managers control for Instruct-o-Mat by keeping
power off the machine
Foul: Enables disabling of the foul communication to the
machine: without disabling the foul light at the approach
Push Button Function Controls
Sweep: Enables running the sweep from the Chassis
Table: Enables running the Table from the Chassis
Reset / Program Zero: Enables zeroing the memory of the Chassis.
Also serves as a manual intervention (a safety feature for mechan-
ics) if the Chassis is shut down. This button “Must be Depressed”
to restart machine
1st – Ball – 2nd: Enables the Mechanic to toggle the machine
between 1st and 2nd ball.
Cycle: Enables the Mechanic to cycle the machine from the Chassis
and operate a Continuous Cycle
Pin: Enables the Mechanic to control the Pin feed solenoid
L & K: Enables the Mechanic to perform a test of all the respot cell
switches
Resetable Breakers
Main Power Circuit Breaker: Shuts down power to the machine
Table Motor: Protects Chassis if motor overloads
Sweep Motor: Protects Chassis if motor overloads
Back-End Motor: Protects Chassis if motor overloads
Solenoid: Protects Chassis if a short occurs
82-30 Pinspotter Products
Solid State 82-30 MP Air Chassis
#823001 (115V/60Hz) AMF #6525....................$1244.00
#823003
(115V/60Hz) AMF #5850....................$1244.00
An Enhanced Direct Replacement Chassis for AMF 82-30 Pinspotters
The “New” Generation
ZOT has reengineered and designed selected components in the 82-30 MP Chassis
and is pleased to introduce the MP Air, a much more user friendly and reliable
pinspotter controller for your AMF 82-30’s.
Check these “all new” added Features and
Benefits:
Circuit Protection: The original Slow-Blow fuse protection has been replaced with four “Resettable” Breakers, all set
at lower amperages than the original fuses, for added protection. If a Breaker trips, simply reset the Breaker after
eliminating the cause of the overload.
Air Cooling System: The internal components of the chassis will be air cooled by a fan mounted in the side panel of the unit.
Just like a computer, the fan runs at all times when power is applied to the Pinspotter , e.g., form the Managers Control.
Replacement Breakers
#220040 12-AMP ..................$15.53
#220039 10-AMP ..................$15.53
1
CTI by ZOT
Improved
Replacement Fuses For
Solid State 82-30 MP Chassis
#220022 15-AMP ....................$2.52
#220009 10-AMP ....................$2.52