Specifications

ISSU Introduction
New and Enhanced Features in AlliedWare Plus 5.4.4 Major and Minor Versions 87
Manual Phase
This phase comprises rebooting each of the line cards. The diagram shown in Figure 2 on
page 87 illustrates ISSU’s manual phase.
Figure 2: Illustration Showing ISSU’s Manual Phase
Initiating the ISSU Automatic Phase
In order to perform an ISSU, the following conditions must be met:
You must have a chassis (or a stack) with more than one CFC960 inserted.
Note that ISSU will not operate with CFC400 cards.
There must be no previous ISSU operation in progress.
The software specified by the CLI must be a valid AW+ release for the running system;
that is, it must be on the same maintenance branch as that used currently. For
example, 5.4.4.
The release that is configured using the boot system command must be available for
all stack members.
Active CFC
New SW
Member CFC
Old SW
Line Card 1 Line Card 2
Active CFC Member CFC
Line Card 1 Line Card 2
1. Reboot some line cards.
This diagram shows line
cards 2 and 4 as having
been rebooted.
2. Reboot all other line cards.
The ISSU process is now
complete.
Line Card 3 Line Card 4
Line Card 3 Line Card 4
ISSU Overview - Manual Phase
ISSU-Manual Phase.eps
New SW
New SW
New SW
New SW
New SW
New SW
Software
Version Messages
Software
Version Messages