Table 3: Parameters in the output of the show card detail command
Parameter Description
Card Chassis number and slot number where the card is installed.
Type Product name of the card installed in the slot. If no card is
installed, but one has been provisioned, then the provisioned
board class is displayed, for example “ge24“. If no card has been
installed or provisioned then “-“ is displayed.
State The current state of the card. One of the following will apply:
Booting The card is currently loading its software
release.
Initializing The card has loaded its software release and
is currently initializing software processes.
Joining The card is communicating with other cards
and is currently in the process of joining the
chassis.
Syncing
Firmware
The Standby Control Fabric Card is running a
different software release to the Active
Control Fabric Card. This software is being
automatically upgraded, so that the Control
Fabric Card can fully join the chassis.
Configuring The chassis configuration is currently being
applied to the card.
Syncing The Standby Control Fabric Card has just
joined and is now configured, but it is still
synchronizing dynamic protocol information
from the Active Control Fabric Card.
Online The card is fully operational.
Provisioned The slot is pre-configured for the insertion of
a card at a later time.
In addition, the Control Fabric Cards will also display in brackets
Active or Standby, depending on whether they are the Active
or Standby Control Fabric Card.
Uptime The time the card has been running for. If the card is not in the
online state then “-” is displayed.
Bootloader
Version
The version of the bootloader that the card has installed on it. If
the card is not in the online state, then “-” is displayed.
Mac Address The hardware MAC address of the card. If the card is not in the
“Online” state then “-” is displayed.
Chassis
management
subnet
address
Displays the stack management subnet address used by the
chassis.