Specifications
ISSU Commands
100 New and Enhanced Features in AlliedWare Plus 5.4.4 Major and Minor Versions
show card
Use this command to display information about current and provisioned slots for chassis
line cards or control cards. Note that when ISSU is actively rebooting CFCs an asterisk is
displayed beside a line card’s state to indicate that the card is not running the same
software version as its Active Master CFC. An explanation line is also added at the end of
the display.
Syntax show card
Mode
Privileged Exec
Example To display summary information about the cards, use the following commands:
Output Figure 4: Example output from the show card command
awplus#
show card
awplus# show card
Card Type State
----------------------------------------------------------------
----------------
1.1 AT-SBx81GP24 Online
1.2 AT-SBx81XS6 Online
1.3 AT-SBx81GP24 Online *
1.4 - -
1.5 AT-SBx81CFC960 Online (Active)
1.6 AT-SBx81CFC960 Online (Standby)
1.7 AT-SBx81GS24a Online *
1.8 - -
1.9 - -
1.10 - -
1.11 AT-SBx81GT24 Online
1.12 AT-SBx81GS24a Online
* Is running a different sw version to the Active CFC -
needs a reboot
Table 2: Parameters in the output of the show card command
Parameter Description
Card Chassis number and slot number of the card installed.
Type Product name of the card installed in the slot. If no card is
installed, but a slot has been provisioned, then the provisioned
board class is displayed, for example “ge24“. If no card has been
installed or slot provisioned then “-“ is displayed.