955 Series Series 956 INSTALLATION MANUAL LINEAR DISPLACEMENT TRANSDUCERS 955S BRIK ™ Smart BRIK LDT ABSOLUTE PROCESS CONTROL KNOW WHERE YOU ARE... REGARDLESS 1080 N. Crooks Road, Clawson, MI 48017-1097 Phone 248-435-0700 Toll Free 800-635-0289 Fax 248-435-8120 www.AMETEKAPT.
Introduction Mounting The 955S Smart Brik is an accurate programmable, auto-tuning, non-contact, linear displacement transducer in an economical, low profile package. The transducer utilizes our field proven magnetostrictive technology to give absolute position, repeatable to .01% of the programmable sensing distance. The streamlined anodized aluminum extrusion houses the sensing element and electronics.
NOTE 3: ZERO or SPAN can be adjusted individually without setting the other. NOTE 4: ZERO = 0V on 0 to 10 VDC units and 4mA on 4 to 20mA units. For your convenience, Ametek offers an in-line programming unit (955-1409) that can be installed inline with the LDT. The in-line programmer uses a rocker switch to program the zero and span. For details, see accessories on page 7.
955S Wiring Connections Wiring Diagram 955S Once the LDT has been installed, wiring connections can be made. There are two groups of connections you will need to make. They are as follows: • Power Supply Connections (including ground and shield) • LDT Input/Output Connections Euro Connector (Micro 12 mm single keyway) Program Input (white wire) Power 10 - 30 VDC (brown wire) Ground (blue wire) Power Supply/Ground Connections The 955S standard cable is a 4 Pin, 12mm, Euro Style cordset.
Dimensions A standard female swivel mounting arm is provided with the slide magnet assembly. For extensions and other options contact the factory. Mounting brackets (SD0522000) slide in the grooves on the side of the extruded housing. When tightened down with fastening hardware the mounting brackets clamp the unit into place. It is recommended to use one mounting bracket on each end and every three feet between. .
FM Approved for Class I, Div II NOTE 1: As an added benefit, the 955S is FM approved for Class I, Div II, Groups A, B, C, D applications when installed and wired per drawing E0241100. 6 NOTE 2: If your application does not require FM Class I, Div II approval, wire the 955S using a standard 4 pin Euro cordset from Ametek or others. 1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.AMETEKAPT.
Float Magnet P/N SD0522100 Accessories Item Part Number Slide Magnet SD0521800 Slide Magnet Side Adapter SD0521801 Float Magnet SD0522100 Mounting Foot SD0522000 6 Ft. Cable 949001L6 12 Ft. Cable 949001L12 6 Ft. Cable, Right Angle Connector 949002L6 12 Ft. Cable, Right Angle Connector 949002L12 Control Arm 955ARMXX (X = Inches) In-Line Programming Unit 955-1409 Rod Ends 04-570252 FM Accessories 6 Ft. Straight Cable 949024L6 12 Ft.
Other Products Copyright 2010 by AMETEK AUTOMATION & PROCESS TECHNOLOGIES. All Rights Reserved. Made in the USA. 1080 N. Crooks Road, Clawson, MI 48017-1097 Phone: 248.435.0700 Toll Free: 800.635.0289 Fax: 248.435.8120 www.ametekapt.com 955S.M4R 9/11.