Owner's manual
2
Permanent 
Magnet
Interrogation Pulse
Patented 
Reflector
t1
t2 (continued)
t2
Magnetostrictive Wire
Magnetostrictive Principle
1. A high current interrogational pulse creates an 
electromagnetic fi eld along the magnetostrictive 
wire. 
2. Interaction with the permanent magnet creates a 
torsional strain pulse that travels up (t
1) and down 
(t
2) the wire. 
3. The torsional strain pulse travels up the wire to a 
small pick up sensor at the top of the transducer. 
The pulse traveling down the wire is refl ected and 
continues up the wire to be sensed by the same 
pick up sensor. 
4. The time between the pulse (t1) and the pulse (t2) 
is used to determine the level.
The 7230 Series HT Digital Probe is a new 
magnetostrictive level measurement system from 
AMETEK APT for the up-stream Oil & Gas Industry 
and high temperature applications that require multiple 
level and temperature measurements. 
Magnetostrictive level measurement technology has 
the capability of providing the highest accuracy of 
any of the most popular level technologies that are 
currently offered in today’s market. The 7230 Series is 
no exception, as it exceeds the high accuracy of the 
proven 7330 Series with an impressive accuracy of 
0.01% of measured span.
The 7230 HT Digital Stik is a level measurement 
solution that provides both total level, interface level 
and up to 5 temperature readings that requires only 
one process connection. The 7230 Series has multiple 
output options, a digital ASCII interface and an RS-485 
Modbus RTU digital output with an optional analog 
interface. The 7230 Series is approved as Explosion 
Proof (without Intrinsic Safety Barriers) for Class I, Div. 
1, and Zone 1 hazardous area installations.
The advantages of magnetostrictive technology 
include high accuracy and reliable level measurement 
capabilities that are completely independent 
of changes in the process material’s electrical 
characteristics and densities. Hydrocarbon based 
condensates have a predictable range of specifi c 
gravity that are well within the range of fl oats that are 
part of this product offering. There is no calibration 
required to set up the probe. Variations in hydrocarbon 
make up will not cause any level measurement errors. 
A choice of two communication protocols are available. 
The 7231 HT has a patented Modbus module that 
provide 12 Register Maps using 16 or 32 bits, with 
either Modbus RTU or ASCII transmission. In 
addition, there is an optional Analog output converter 
available for 4-20mA applications. The 7235 HT 
has a proprietary ASCII digital output and would be 
recommended for OEM use. The new sensor has 
an explosion proof approval for use in Class I, Div. I, 
Group A, B, C, and D hazardous area installations.
The advantages of magnetostrictive technology 
include high accuracy and repeatability, plus reliable 
level measurement capabilities that are completely 
independent of the process materials electrical 
characteristics. The standard fl oat is suitable for most 
liquids with a minimum density of 0.5 specifi c gravity. 
Section 1 - 7230 Series HT Digital Probe 