Owner manual
Installation and Programming Manual
50
Appendix A: Error Messages
51
Installation and Programming Manual
Appendix A: Error Messages
The following charts contain descriptions and solutions for the three types of errors that can appear
on the monitor’s LED display. To clear errors, perform the solutions found in charts A-1, A-2, and
A-3, followed by pressing either the scroll, shift, or enter.
Chart A-1 System Errors
Chart A-2 Operating Errors
Error Displayed Error Description Solution
SEr101 A conguration error has occurred. Contact GEMCO Tech. Support.
SEr102 The monitor's function parameter
memory has been corrupted.
Contact GEMCO Tech. Support.
SEr103 The battery for the monitor's memo-
ry is low.
Contact GEMCO Tech. Support.
SEr104 A software fault has occurred. Contact GEMCO Tech. Support.
SEr105 An error has occurred with the
monitor's internal memory locations.
Clear the error and contact GEMCO
Tech. Support.
SEr106 A rmware CRC error has occurred. Contact GEMCO Tech. Support.
SEr320 This is a resolver-specic error. See
Chart A-6.
SEr330 The input device is not connected to
the monitor's input module.
Connect the input device to the
input module and clear the error.
SEr331 This is an LDT-specic error. See
Chart A-7.
Error Displayed Error Description Solution
OEr101 The press's ram did not move within
the time programmed in the Move
Detection Time-Out function.
Review press operation and/or in-
crease the value of the Move Detec-
tion Time-Out function.
OER330 or
OEr320
The press's shut height moved be-
yond the value programmed in the
Negative Over Travel Limit Func-
tion.
Review press operation and/or
increase the value of the negative
Over Travel Limit function.
T13692 appendix a.indd 3/17/04, 6:54 AM51