955
12 PIN CONNECTOR VIEW
Wiring Diagram ( Connector Option E )
Wiring Diagram ( Connector Option H )
10 PIN HIROSE CONNECTOR VIEW
Part Numbering
955CDQ 0120
S
E
Connector Option
H
HRS environmental connector
E
Euro 12 Pin, 12mm connector,
consult factory for others
955CDQ
Quadrature
1000
Output Resolution
Cycles per inch, maximum internal
resolution is 0.001 inches 1000 standard
(available range is 0001 through 9999)
X1F7E
Input
E
Sinking (typically used with
sourcing output type)
C
Sourcing (typically used with
sinking output type)
T
TTL Level
Output Mode
X1
X1 quadrature, consult factory
for other output modes
Quadrature Cycle Output
Frequency Range
A1
1 kHz
A2
2 kHz
A3
5 kHz
F1
10 kHz
F2
25 kHz
F3
50 kHz
F4
75 kHz
F5
100 kHz
F6
150 kHz
F7
250 kHz
F8
500 kHz
F9
1 MHz
N XD
Output Drivers
D
Differential RS422 line driver,
TTL compatible
L
Differential line driver
10 to 30 VDC, V out = V in
(LDT Power) -1 Volt
Zero Offset Storage
V
Volatile (non retentive)
N
Nonvolatile (retentive, 100,000
storage cycles maximum)
Stroke Length
Insert stroke to 0.1” as a four-place
number, enter 12.0” stroke as 0120.
OR
Insert stroke in millimeters to 1mm.
Enter as a four-place number
followed by ‘M’. Example: 305mm
stroke entered as 0305M.
Item Part Number
TopMountingFoot(2min.required) SD0522000
EndMountingFeet- Setincludes2pieces SD0530600
SideMountingFeet-Setincludes4pieces SD0559200
6Ft.Cable(OptionHConnector) SD0527700L6OBSOLETEConsultFactory
12Ft.Cable(OptionHConnector) SD0527700L12OBSOLETEConsultFactory
25Ft.Cable(OptionHConnector) SD0527700L25OBSOLETEConsultFactory
6Ft.,12Pin(OptionEConnector) 949023L6
12Ft.,12Pin(OptionEConnector) 949023L12
Accessories for 955CDQ
For non-standard lengths, consult factory.
Options
X
No options
E
Wet environment, electronics
sealed to IP68 rating,
connector option E only
Cylinder Magnet Polarity
S = South Pole facing LDT - Typical
N = North Pole facing LDT
Note: It is important to identify the
polarity of the magnet installed in the
cylinder. Most Pneumatic cylinder
manufactures typically install the
magnet with the South Pole facing
out, but we have experienced both
North and South Pole magnets.
955CDQ BRIK Gen III