User Manual
29
1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.ametekapt.com
AUTOMATION & PROCESS
TECHNOLOGIES
953
Analog Part Numbering
SSI Part Numbering
953A 0120V0 X
Stroke Length
Insert stroke length to 0.1 inch. Enter as a four-place
number. Example: A 12.0” stroke enters as 0120.
OR
Insert stroke in millimeters to 1mm. Enter as a
four-place number. Example: 305mm stroke entered
as 0305M. Metric length includes metric mounting,
M18x1.5. Unless Specified Otherwise.
SXX
Null Zone
X
Standard 2 inches.
N
Insert non-standard Null Zone
(1.5” Minimum).
This value is called out in inches
regardless of units of measure
(i.e. 1.5” Null Zone = N1.5)
Units of Measure
Blank
Inches.
M
Metric
Options
X
None
S
Stainless Steel cover and
connector. Only available
with connector options S,
C, and H.
Dead Band
X
Standard 2.5 inches.
D
Insert non-standard Dead
Band (2.25” Minimum)
This value is called out in
inches regardless of units
of measure (i.e. 2.25”
Dead Band = D2.25)
Output
V0
0 to 10 VDC
V1
10 to 0 VDC
V2
-10 to 10 VDC
V3
10 to -10 VDC
V4
0 to 5 VDC
V5
5 to 0 VDC
V6
-5 to 5 VDC
V7
5 to -5 VDC
C4
4 to 20mA
C2
20 to 4mA
Connector Option
S
Standard 5 Pin, 12mm Euro
C_
Integral Cable Assembly. Insert length in
feet. Example: C6 = 6 foot cable.
M
6 Pin DIN, MTS Style D60
B
8 Pin DIN, Balluff S32
E
Environmental 10 Pin MS Connector
compatible w/951 & 952 LDTs w/
connector option “E”
.
H_
High Temp., Integral cable assembly
200º C Teflon Cable. Insert length in feet.
Example: H6= 6 foot High Temp Teflon
Cable.
Optional Housing Style
- Mounting Threads
Blank
Raised face hex
base (standard) -
Threads will be the
same as “Units of
Measure” unless
specified otherwise.
R
US Threads with
raised face hex
base
F
US Threads with
flat face hex base
M
Metric Threads with
raised face hex
base
N
Metric Threads with
flat face hex base
C
Sensor cartridge
only - No hex base
VP953S 0120 1
Stroke Length
1" to 300". Insert stroke length to 0.1 inch. Enter
as a four-place number. Example: A 12.0” stroke
enters as 0120.
OR
Insert stroke in millimeters to 1mm. Enter as
a four-place number. Example: 305mm stroke
entered as 0305. Metric length includes metric
mounting, M18x1.5. Unless Specified Otherwise
SXX
Null Zone
X
Standard 2 inches.
N
Insert non-standard Null Zone
(1.5” Minimum).
This value is called out in
inches regardless of units of
measure (i.e. 1.5” Null Zone
= N1.5)
Data Length
1
24 Bits
2
25 Bits
3
26 Bits
B
Data Format
B
Binary
G
Gray
X
Options
X
None
A
Alarm Bit 25, Parity 26
S
Stainless Steel cover and
connector. Only available with
connector options S, C and H.
Units of Measure
Blank
Inches
M
Metric
S
Position Update
S
Synchronous
A
Asynchronous
F
Direction
F
Measures Direction Forward
R
Measures Direction Reverse
V
Velocity
1
Resolution
1
.005mm
2
.01mm
3
.05mm
4
.1mm
5
.02mm
6
.002mm
7
.001mm
8
.00005"
9
.0001"
A
.0005"
B
.001"
Optional Housing Style
- Mounting Threads
Blank
Raised face hex
base (standard) -
Threads will be the
same as “Units of
Measure” unless
specified otherwise.
R
US Threads with
raised face hex
base
F
US Threads with
flat face hex base
M
Metric Threads with
raised face hex
base
N
Metric Threads with
flat face hex base
C
Sensor cartridge
only - No hex base
Connector Option
S
Standard 6 Pin, 12mm Euro
C_
Integral Cable Assembly. Insert length in feet. Example: C6 =
6 foot cable.
M
7 Pin DIN, MTS Style D70
B
8 Pin DIN, Balluff S32
E
Environmental 10 pin MS connector compatible with
SDO439700 LXX cable assembly
H_
High Temp., Integral cable assembly 200º C Teflon Cable.
Insert length in feet. Example: H6= 6 foot High Temp Teflon
Cable.
Dead Band
X
Standard
2.5 inches
.
D
Insert non-standard Dead Band
(2.25” Minimum)
This value is called out in inches
regardless of units of measure (i.e.
2.25” Dead Band = D2.25)
953A/D/SSI VMAX
™
LDT