User Manual
24
1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.ametekapt.com
AUTOMATION & PROCESS
TECHNOLOGIES
952
TheBlueOxQuadratureisamagnetostrictivelinear
displacementtransducer(LDT)forcontinuous
machinepositioninginavarietyofindustrial
applications.Thequadratureoutputmakesit
possibleforcustomerstohaveadirectinterfaceto
virtuallyanyincrementalencoderinputorcounter
card,eliminatingcostlyabsoluteencoderconverters
andspecialPLCinterfacemodules.
TheBlueOxQuadratureLDTislabtestedandeld
proventostanduptohighshockandvibration
withouteffect.Withtestresultsof2,000Gsofshock
and30Gsofrandomvibrationwithoutfalsesignals
ormechanicaldamage,theBlueOxQuadrature
LDTisreadytoperforminthemostdemanding
applications.
TheBlueOxQuadratureLDTcanbeorderedwith
1to9999cyclesperinchofoutputresolution
andthepositiondataisabsolute.Thetransducer
featuresaninputtore-zerotheprobe“onthey”.
Anotheruniquefeatureisthe“burst”mode.An
inputonthetransducertriggersadatatransfer
ofalltheincrementalpositiondatarelativetothe
transducer’sabsolutezeroposition.Thiscanbe
usedtoachieveabsolutepositionupdateswhen
powerisrestoredtothesystem.
TheBlueOxQuadratureisshippedfromthefactory
pre-calibratedandreadyforinstallation.Inaddition
toitsabilitytowithstandshockandvibration,
theBlueOxQuadratureisruggedinotherways.
Sensingtubeconstructionisweldedstainless
steel,suitableforinsertionin5,000PSIhydraulic
cylinders.
Theelectronicsareenclosedbehindanaluminum
housingwithO-ringseals.TheBlueOxQuadrature
LDT,withitsruggedconstruction,isathomein
heavydutyareassuchaslumbermills,steelmills,
stampingplantsandanyotherharshenvironment
whereaccurateandreliablecontinuouslinear
positionsensingisneeded.
Specifications
Input Voltage
13.5 to 26.4 VDC
Current Draw
< 200mA at 15 VDC
Output
Quadrature Output A+, A-, B+, B-, Z+, Z-.
Line Drivers: 5V or Input Power
Inputs
10 to 30 VDC
Resolution
0.001”
Linearity
<.05% (+/- .002” Min)
Repeatability
0.001% of Full Stroke (+/- .002” Min.)
Hysteresis
+/-.02% of Full Scale
Operating Temperature
Head Electronics
Guide Tube
-40° to 155° F (-40° to 70° C)
-40° to 220° F (-40° to 105° C)
Operating Pressure
5000 PSI Operational, 10,000 PSI Spike
Span Length
2” to 168”
Null Zone
2.0”
Dead Band
2.5”
Connectors
1/4 Turn MS Connector Standard. Potted Pigtail Assembly
Available Optionally
Update Time
Approx. 1ms for 1” to 50”
Approx. 2ms for 51” to 100”
Approx. 3ms for 101” to 150”
Approx. 4ms for 151” to 168”
Enclosure
IP67
Specications are subject to change without notice.
Specications are based on a typical 36” LDT .
952QD BlueOx Magnetostrictive
LDT with Quadrature Output