User Manual

16
1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.ametekapt.com
AUTOMATION & PROCESS
TECHNOLOGIES
950MD
Note 1:Guidetubesupportbracketsaresuppliedasstandardfor
strokesof72”orgreater.
Note 2:Specialhightemperature,abrasionresistantandoilresistant
cablesareavailable.ConsultyourCustomerServiceRepresentative.
Accessories
Item Part Number
Vortex Cooler 04578009
Mufer for Cooler 04578010
Replacement 1/2” Spherical Rod End 04570140
Guide Tube Support Bracket (See note 1) C0903400
Replacement (Male Connector) for Option “C2” Connector 04521407
Female Mating Connector for Option “C2” Connector 04521372
Replacement (Male Connector) for Option “C3” Connector 04521568
Replacement Piston & Magnet Sub Assembly SD0452400
Replacement Housing bushing & Seal Sub Assembly SD0563300
950MD Compatibility Guide
940 Yes
950IS Consult Factory
951 Yes (Must be ordered w/2” Null Zone & 5” Dead Band)
952 Yes (Must be ordered w/2” Null Zone & 5” Dead Band)
953 Yes (Must be ordered w/2” Null Zone & 5” Dead Band)
955 See 956 Section
7330 Consult Factory
950 LDT Cable Assemblies
Item Part Number
Cable Assembly with Mate for Option “C” Connector Style,
6 Feet, (For 950-CP)
SD0436700L6
Cable Assembly with Mate for Option “C” Connector Style,
6 Feet, (For 950A/950TP)
SD0436000L6
951, 952 and 953 LDT Cable Assemblies
Item Part Number
Cable Assembly with Mate for Option “C2”, C5S, and C5D
Connector Styles, 6 Feet
SD0439700L6
5 Pin, Straight, Stainless Steel Cable Assembly with Mate for
Option “C3” Connector Style, 6 Feet
949013L6
6 Pin, Straight, Stainless Steel Cable Assembly with Mate for
Option “C4” Connector Style, 6 Feet
949031L6
Part Numbering
950MD 12A
0B
Fully Retracted
Overstroke in Inches
Insert length of retract overstroke
in inches followed by “B”. If no
retract overstroke is required,
simply insert “0B”.
0C
XX
Options
X
None
V
Vortex air cooler
B1
Protective boot - neoprene coated nylon
(-60F to +250F )
B2
Protective boot - silicone coated ber glass
(-100F to +550F )
B3
Protective boot - teon coated ber glass
(-100F to +500F )
R
Rear mount spherical rod end 3/4”
F
Front mount spherical rod end 3/4”
RS
Stainless steel rear mount spherical rod
end 3/4” with 304 stainless steel mounting
bolt
FS
Stainless steel front mount spherical rod
end 3/4” with 304 stainless steel mounting
bolt
L
Delron liner for extended life cycle on
longer horizontal applications (used to
protect the LDT’s rod assembly)
SB
304 stainless steel boot
A
Barrel air purge
Active Stroke in
Inches
Determine the “active”
stroke to be measured
followed by “A”.
Fully Extended
Overstroke in Inches
Insert length of extend overstroke in
inches followed by “C” If no extend
overstroke is required insert “0C”
Connector
X
Standard 1/2 inch NPT conduit tting
(It is suggested to order a quick disconnect connector
on the LDT)
C2
Environmental 10 pin MS connector and mate on side
of housing (for use with 951, 952, and 953 LDT’s with
connector option E only)
C3
5 Pin, 12mm, Euro Connector on Side of Housing (for
952A /953A w/connector option S only)
C4
6 Pin, 12mm, Euro Connector on Side of Housing (for
953D and SSI w/connector option S only)
C5A
10 Pin STD - to 953A 5 Pin Euro
C5D
10 Pin STD - to 953D 6 Pin Euro
NC
No Head Cover on the 950MD Housing
W
Special Head cover for LDTs using a water cooled
jacket. Allows entry and exit of water lines. NOTE:
This option does not support connector option C, C2
or C3.
CGP
Cord grip PVDF for cable diameter .1”-.3”
CGA
Cord grip stainless steel for cable diameter .19”-.25”
CGB
Cord grip stainless steel for cable diameter .25”-.31”
CGC
Cord grip stainless steel for cable diameter .31”-.38”
950MD Mill-Duty Housing