Installation & Programming Manual
Chapter 3: Set-Up & Programming
Command 6: Reset-to-Preset Data
This command will program the reset-to-preset value for each resolver. The parameters for this
command have been defined below:
elbaTegamItuptuOnoitpircseD
0droW retsigeRtiB
1droWretsigeRdnammoC )6(
2droW (1tupnirofeulaVteserP-ot-teseR1retemaraP )drowhgih
3droW1tupnirofeulaVteserP-ot-teseR2retemaraP )drowwol(
4droW 2tupnirofeulaVteserP-ot-teseR3retemaraP )drowhgih(
5droW2tupnirofeulaVteserP-ot-teseR4retemaraP )drowwol(
6droW )0(devreseR5retemaraP
7droW)0(devreseR6retemaraP
NOTE: The reset-to-preset command is only valid if the module has been set up for
configurations 3, 4, 5 and 6.
Parameter 1 contains the motion detect RPM value. This value can range from zero to 65,535. The
default value is zero. When the RPM is greater than or equal to this value, a motion detect bit will be
set in the input image table. A zero value will disable the motion detect.
NOTE: This command is only valid if the module has been set up for configurations 1, 2 or 6.
Parameters 1 and 2 contain the position that resolver #1 should reset to when input 1 is activated.
Parameters 3 and 4 contain the position resolver #2 should reset to when input 2 is activated. When
this command is received, the software will verify that the reset-to-preset values are valid positions*.
The default values for the reset-to-preset values is zero.
* If turns counting is disabled or configured for multi-turn, the position must be between zero
and the scale factor. If turns counting is enabled, the position must be between zero and
2,147,483,647.
Command 7: Save Configuration
This command will save the data to the EEPROM. The parameters for this command have been
defined below:
elbaTegamItuptuOnoitpircseD
0droW retsigeRtiB
1droWretsigeRdnammoC )5(
2droW MPRtceteDnoitoM1retemaraP
3droW)0(devreseR2retemaraP
4droW )0(devreseR3retemaraP
5droW)0(devreseR4retemaraP
6droW )0(devreseR5retemaraP
7droW)0(devreseR6retemaraP