TDS
Table Of Contents
- Stock Code
- BWRF Series
- Packaging Information
- Characteristics
- Compliance
- Surface Preparation
- Concrete
- Concrete Masonry Unit (CMU)
- OSB, Plywood, Lumber, Pressure-Treated Wood
- Application Methods
- Application Instructions
- The information and specifications set forth in this Technical Data Sheet are based on tests conducted by or on behalf of Ames Research Laboratories, Inc. All information is subject to change and pertains to the product available at time of publicatio...
Technical Data Sheet
Block & Wall™ Liquid Rubber
Ames Research Laboratories, Inc.
1891 16
th
St SE | Salem, OR 97302
888-345-0809 | productservices@amesresearch.com
8.2-TBWR 4/20/21
Stock Code
BWRF Series
Packaging Information
• 1 Gallon Pail
• 5 Gallon Pail
Characteristics
Block & Wall™ Liquid Rubber is a blend of adhesive, high strength,
elastomeric, liquid rubber designed for waterproofing basement
walls and below grade foundations. With up to 1800% elongation,
Block & Wall™ Liquid Rubber adheres to concrete, galvanized steel,
aluminum, and plywood. Block & Wall™ Liquid Rubber dries to a
tough elastic membrane that resists cracking and peeling.
VOLUME SOLIDS 41% ± 2%
WEIGHT SOLIDS 45% ± 2%
COLOR White
DRY TIME 24 hours between coats
CURE TIME 7-10 days
COVERAGE
1 gallon per 100 sq. ft. per coat
(2 coats recommended)
DRY FILM THICKNESS
(@ 1 GAL/100 SQ. FEET)
6 mils per coat
(minimum of 2 coats)
ELONGATION
ASTM D2370 up to 1800% at 20 mils
DFT
FINISH
Semi-Gloss
Should be top coated with Block & Wall™ Acrylic
FLASH POINT >200° F
HUMIDITY Best applied at 50% humidity or below
MOLD & MILDEW
RESISTANCE
No Growth
PH AS SHIPPED ASTM E70 8.50-9.0
TENSILE STRENGTH
ASTM D2370 up to 200 psi at 20 mils
DFT
SHELF LIFE 24 Months Unopened
V.O.C CONTENT < 10 g/l
VAPOR
PERMEABILITY
ASTM E96 Desiccant Method 0.10
perms
VEHICLE TYPE Styrene Butadiene
VISCOSITY
ASTM D2196 Brookfield Spindle #6
@100 rpm 5000-6000 cps
ADHESION
Cross hatch adhesion dry 0% loss of
adhesion on galvanized steel, treated &
untreated aluminum, concrete, &
plywood
Compliance
SCAQMD Yes
OTC & OTC PHASE II Yes
CARB & CARB SCM
2007
Yes
LEED® V4 & V4.1
EMISSIONS
Yes
LEED® V4& V4.1 Yes
Surface Preparation
All surfaces must be sound and free of spalled areas, loose nails, screws, sharp
protrusions, frost, dirt, grease, oil, or other matter that will hinder the
adhesion of the membrane installation. Clean loose dust and dirt from the
surface by brushing or wiping with a clean, dry cloth, brush, or broom.
Pressure wash if appropriate for the job conditions.
Concrete
Should be cured in place 28 days minimum. All surfaces need to be smooth,
with sharp protrusions such as cold joints ground flush. Honeycomb, holes,
cracks, and joints exceeding 1/8”and up to 5/8” across shall be filled with Blue
Max® Trowel or Blue Max® Caulk.
Concrete Masonry Unit (CMU)
Mortar joints shall be struck flush and free of voids exceeding 1/8” across.
Mortar droppings shall be removed from brick ties and all other surfaces
accepting Block & Wall™ Liquid Rubber Membrane and accessories. Allow
mortar joints to dry a minimum of 28 days prior to application of the Block &
Wall™ Liquid Rubber and accessories.
OSB, Plywood, Lumber, Pressure-Treated Wood
Wood and wood sheathing need to be flush at joints with gaps between
boards according to building codes and manufacturer requirements.
Moisture content, measured with a wood moisture meter in the core of the
substrate, requirement is below 20%. Do not cover any wooden materials
with Block & Wall™ Liquid Rubber and/or accessories if moisture content is
20% or above.
Application Methods
Apply between 50° - 90° F on a warm dry surface. Surface temperature must
be 5° F higher than the dew point and rising
• Brush: Nylon/polyester
• Roller: 3/8" - 1/2" nap nylon/polyester
• Sprayer: Always use airless equipment
Small Projects – Flow rate of 0.60 GPM (i.e. Graco 495 airless). 2500 - 3000
psi. Tip size 0.412 to 0.521. Hose size 1/4 in.
Large Projects – Flow rate of 1.0 - 2.0 GPM (i.e. Graco 695 airless). 2500 to
3000 psi. Tip size .417 to .625. Hose size 1/4 in. to 3/8 in.
Application Instructions
Review product Application Guide before proceeding. Contact Ames
Research Laboratories Technical Service Representatives
for questions
pertaining to the coating system application and required coating film
thickness. Conduct a test patch to ensure proper adhesion.
• Block & Wall™ Liquid Rubber must be top coated with a high-quality
acrylic paint for all exterior exposures. On interior surfaces Block & Wall™
Rubber must be top coated with a high-quality acrylic paint for washability
• Do not apply Block & Wall™ Liquid Rubber if the temperature is expected
to drop below 32° F within 24 hours of application.
• Do not apply in high heat areas of 180° F
• Do not apply over wet substrates
Disclaimer
The information and specifications set forth in this Technical Data Sheet are
based on tests conducted by or on behalf of Ames Research Laboratories, Inc.
All information is subject to change and pertains to the product available at
time of publication. Please contact Ames Research Laboratories to receive
the most recent Technical Data Sheet.
Clean-up, Storage & Disposal
• Clean up application equipment, tools, spills, hands immediately after use
with water
• Store unused product in the original container tightly sealed
• Dispose of this product in accordance with local, state, or federal
requirements
• Protect from freezing
Cautions
• Do not take internally
• Keep out of reach of children
• Avoid contact with skin and eyes
• Use hand and eye protection when using this product
• Wash with soap and water after contact with skin
• If eye-contact occurs rinse with clean water and seek medical advice if
symptoms continue