Drilling:
Temperaturechangecausesexpansionandcontractionandanyresistancecan
causesheetdistortion.Therefore,fixingholesmustbepre‐drilledforeachfastener
toallowforthisthermalmovement.
Usinga¼”inchbit,pre‐drillaholeinthepanelforeachfastener.
Pre‐drillholes3/32”largerthanscrewdiametertoallowforexpansionandcont raction.
Drillsheetsatalowspeed,supportingthesheetunderneathtoavoidunnecessaryvibration.
Sheetsmaybedrilledusin
gany
commonpowerdrillintendedformetal.
Drillholesthroughthecrestofthecorrugationforroofingandthroughthevalleysforwalls.
Drillingdebriscaneasilybeblownaw aywithcompressedair.
Fastening:
Startfasteningthesheetatthebottom,movingtowardsthetopofpanel.Donotfastenatbothends
andmovetowardsthemiddle.Attachthesheettothepurlinsusingfastenersrecommendedforyour
specificapplication.
Fastensheetsatthepeakofeveryothercorrugationforbothroofapplicationsandwallapplications.
Sheetedgesattheridgeandguttershouldalsobefastenedateveryothercorrugation.
Fixingwithatleast½”neoprenebondedwashersisrecommended.
Drivefastenersperpendiculartothecorrugatedsheet.
Doublecheckthatallfastenersareprop
erlysecured.
Acorrectly
installedfastenerwillsitflushagainstthepanel.Makeadjustmentsasneeded.
Donotovertightenscrews.Overtighteningcausessheetdistortion,leadingtocracksandfractures.